Noninvasive Doppler echocardiographic evaluation of shunt flow dynamics of the ductus arteriosus.
نویسندگان
چکیده
The pulsed Doppler technique was used to record the flow velocity patterns in the ductus arteriosus and the pulmonary artery in 26 patients with either isolated or complicated patent ductus arteriosus (PDA). In all patients, abnormal Doppler signals indicating left-to-right (L-R) or right-to-left shunt flow or both could be obtained at the site of the ductus arteriosus. These Doppler flow patterns determined within the ductus coincided with the direction of ductal flow seen on the contrast two-dimensional echocardiogram. No Doppler signals of shunt flow were demonstrated in any of 42 control subjects. The peak, mean, and diastolic velocities of the L-R shunt flow within the ductus were measured from the ductal flow velocity profiles. With the Doppler-derived measurements of the mean and diastolic velocities, patients with normal pulmonary arterial pressure and those with evidence of pulmonary hypertension could be correctly identified. In addition, the mean velocity of the diastolic antegrade flow portion obtained from the proximal left pulmonary artery, which was related to ductal L-R shunting, was measured in 16 patients with isolated PDA. This Doppler flow determinant showed a good linear correlation with the L-R shunt ratio determined by Fick's method (r = .88, p less than .01). Our technique permits the noninvasive evaluation of shunt flow dynamics in patients with PDA.
منابع مشابه
DIAGNOSTIC METHODS CONGENITAL HEART DISEASE Noninvasive Doppler echocardiographic evaluation of shunt flow dynamics of the ductus arteriosus
The pulsed Doppler technique was used to record the flow velocity patterns in the ductus arteriosus and the pulmonary artery in 26 patients with either isolated or complicated patent ductus arteriosus (PDA). In all patients, abnormal Doppler signals indicating left-to-right (L-R) or right-to-left shunt flow or both could be obtained at the site of the ductus arteriosus. These Doppler flow patte...
متن کاملEchocardiographic assessment of patent ductus arteriosus shunt flow pattern in premature infants.
AIMS To identify the patent ductus arteriosus (PDA) shunt flow pattern using Doppler echocardiography; and to assess whether it could be used to predict the development of clinically significant PDA. METHODS Premature infants weighing under 1500 g, who required mechanical ventilation, and in whom daily echocardiography could be performed from day 1 until the ductus closed, and on day 7 to con...
متن کاملQuantification of left-to-right shunt through patent ductus arteriosus by colour Doppler in children admitted for a device closure.
PURPOSE Our animal model suggests that quantification of ductal flow from colour Doppler pixels is possible. We aimed to clarify whether this method can be used to determine a clinically significant ductal shunt in children. METHODS We retrospectively quantified ductal flow from saved images from 20 children who had been admitted for device occlusion of patent ductus arteriosus. Colour Dopple...
متن کاملTwo-dimensional echocardiographic and color flow Doppler evaluation of ductal occlusion with the Rashkind prosthesis.
To evaluate the results of ductal occlusion with the Rashkind prosthesis, 78 children (group 1, 19 boys and 59 girls; mean age at occlusion, 4.5 +/- 4.0 years) with isolated patent ductus arteriosus (n = 73) or in association with other lesions (n = 5) were evaluated by pulsed and color flow Doppler 9 +/- 7 months (range, 2-26 months) after occlusion. Thirty children who had undergone patent du...
متن کاملBlood flow pattern of the interatrial communication in patients with complete transposition of the great arteries: a pulsed Doppler echocardiographic study.
We analyzed blood flow pattern in the interatrial communication in 24 patients with complete transposition of the great arteries (TGA). Eight had TGA with atrial shunt (group 1), nine had TGA with patent ductus arteriosus or ventricular septal defect (group 2), and seven had pulmonary arterial banding and Blalock-Taussig shunt (group 3). The flow pattern was determined at the site of atrial sep...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 75 6 شماره
صفحات -
تاریخ انتشار 1987