Photon Attenuation Correction in Misaligned PET/CT Cardiac Perfusion Images

نویسندگان

  • Axel Martinez-Möller
  • Nassir Navab
  • Markus Schwaiger
  • Stephan G. Nekolla
چکیده

The purpose of this work is to understand, quantify and minimize the impact of the emission-transmission misalignment which has been reported as a source of artefacts in cardiac PET/CT. A new and fully automatic correction algorithm is proposed to realign the μ-map contour of the left ventricle to the measured PET. PET/CT NH3 rest/stress scans were acquired for 16 patients in order to evaluate the consequences of the misalignment and the uptake recovery achieved by the algorithm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions.

UNLABELLED CT-based attenuation correction is a widely used option in commercial PET/CT scanners. However, as a result of a nonsimultaneous acquisition and differences in temporal resolution between both modalities, a potential misregistration between the PET and CT, especially in the thorax and the upper abdomen, can be found. We observed a substantial number of apparent perfusion defects in s...

متن کامل

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Photon Attenuation Correction in Misregistered Cardiac PET/CT

PET-CT misalignment has been reported as a source of artefacts in cardiac PET/CT due to a biased photon attenuation correction. Using the data from 28 cardiac PET/CT rest/stress examinations, PETCT misalignment was corrected using three different methods: manual registration, automatic mutual information based image registration and an emission-driven correction algorithm. The clinical effects ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005