BACKGROUND This randomized single-blinded, cross-over study was done to evaluate the influence of the size of tracheal tubes on air leaks around the cuffs. METHODS In a benchtop model, the number of longitudinal folds on the cuffs was evaluated for different sizes of tracheal tubes. In an anesthetized patient study, thirty patients scheduled for elective surgery under general anesthesia were included. After induction of anesthesia, the trachea was intubated with two sizes of tracheal tubes in a random sequence: in men, internal diameter of 7.5 mm and 8.0 mm; in women, internal diameter of 7.0 mm and 7.5 mm. After tracheal intubation with each tube, air leak pressures were evaluated at intracuff pressures of 20, 25 and 30 cmH(2)O by auscultation. To calculate the tracheal tube resistance (R), an inspiratory pause of 20% was applied and the resulting peak airway pressure (P(peak)), plateau pressure (P(pl)) and mean expiratory tidal volume (Flow) were inserted in the formula R = (P(peak) - P(pl))/Flow. RESULTS More longitudinal folds of the tracheal tube cuffs occurred in larger sized tubes compared to the smaller ones in a benchtop model. Air leakage was significantly less for the smaller tracheal tubes than for the larger ones for each gender at intracuff pressures of 20, 25 and 30 cmH(2)O. Tracheal tube resistances were not significantly altered by the size of tracheal tube. CONCLUSIONS The use of a smaller tracheal tube within an acceptable size can reduce air leakage around the cuff without significantly changing the tracheal tube resistance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of pilot balloon design on estimation of safe tracheal tube cuff pressure.

We studied the effect of pilot balloon design on the ability of experienced anaesthetists to assess and inflate tracheal tube cuffs to safe pressures. A model trachea was designed, incorporating a degree of compliance and an air leak, to evaluate six different pilot balloons grafted onto identical tracheal tubes. Pilot balloons were inflated to one of four pressures and anaesthetists were asked...

متن کامل

Rapid pressure compensation by automated cuff pressure controllers worsens sealing in tracheal tubes.

BACKGROUND Cyclic redistribution of air within the cuff during respiratory pressure changes creates a self-sealing mechanism which allows tracheal sealing, despite tracheal airway pressure being above baseline cuff inflation pressure. The aim of the present study was to investigate the effect of continuous automated cuff pressure regulation on tracheal sealing during cyclic respiratory pressure...

متن کامل

A method for comparing endotracheal cuffs. A controlled study of tracheal trauma in dogs.

Damage to the trachea produced in dogs by large and small residual volume cuffs during 6 h of IPPV was compared using a specially designed endotracheal tube. The cuffs under evaluation were adjusted to exert similar average pressures on the tracheal wall, so that many of the variables believed responsible for tracheal injury were controlled. The true compliance of the cuff was measured with the...

متن کامل

The pressure exerted on the tracheal wall by two endotracheal tube cuffs: A prospective observational bench-top, clinical and radiological study

BACKGROUND The Lotrach endotracheal tube has a unique low-volume, low-pressure (LVLP) cuff, which has been designed to prevent pressure injury to the tracheal wall. We aimed to estimate the pressure exerted on the tracheal wall by the LVLP cuff and a conventional cuff in a bench-top, clinical and radiological study. METHOD In the bench-top study, a model trachea was intubated with the LVLP cu...

متن کامل

Uncuffed versus Cuffed Endotracheal Tubes

SPA-APA Meeting San Francisco 2007 1 Uncuffed versus Cuffed Endotracheal Tubes Markus Weiss, MD, Zurich, Switzerland During the last five decades, uncuffed tracheal tubes were recommended for routine use in children aged below 8 years. Cuffed tracheal tubes in patients younger than 8 years of age were only exceptionally used for special indications. In the last 10 years a change in clinical pra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 61  شماره 

صفحات  -

تاریخ انتشار 2011