Laboratory assessment of thermal characteristics of three phacoemulsification tip designs operated using torsional ultrasound
نویسنده
چکیده
PURPOSE Ultrasound activation of phacoemulsification (phaco) tips can create considerable thermal energy that may increase the risk of tissue damage during cataract surgery. The purpose of this study was to define the thermal profiles of three phaco tip designs in simulated surgical conditions. METHODS In this laboratory investigation, sleeved phaco tips (mini-flared Kelman(®) tip with aspiration bypass port and Intrepid(®) Balanced Tip with aspiration bypass port, and MST A1 bent-mini phaco tip (without aspiration bypass) were tested using an ultrasonic phaco device operated in torsional mode at power levels of 50%, 75%, and 100% amplitude. An automated fixture applied a 30 g load to simulate compression against the incision site, leading to friction between the silicone sleeve and the titanium tip. Temperature was recorded by high rate infrared imaging under conditions of free flow and occlusion, which was simulated by clamping the aspiration line. Data were summarized using descriptive statistics. RESULTS Baseline temperatures of ~26°C were observed for all tips. During ultrasonic operation at 50%, 75%, and 100% amplitude, temperatures were lower for the mini-flared and balanced tips versus the bent-mini tip, both when load was applied and during occlusion. The bent-mini tip reached temperatures as high as 70°C during occlusion with load when operated at 100% amplitude, whereas the mini-flared tip remained <50°C, and the balanced tip remained <36°C in all test conditions. For the mini-flared and balanced tips, temperature increases during operation were not markedly different from free flow and no-load conditions when occlusion or frictional events were simulated. CONCLUSION In all experiments for each tip design, increasing ultrasound power was associated with greater increases in tip temperature. Tip temperatures increased with applied load, but marked temperature increases during occlusion were observed only with the bent-mini tip. The balanced tip produced minimal thermal peaks in all tests.
منابع مشابه
Thermal characterization of phacoemulsification probes operated in axial and torsional modes.
PURPOSE To analyze temperature increases and identify potential sources of heat generated when sleeved and sleeveless phacoemulsification probes were operated in axial and torsional modes using the Infiniti Vision System with the Ozil torsional handpiece. SETTING Phacodynamics Laboratory, Pasteur Ophthalmic Clinic, Santiago, Chile. DESIGN Experimental study. METHODS Two computer-controlle...
متن کاملFluid dynamics, cavitation, and tip-to-tissue interaction of longitudinal and torsional ultrasound modes during phacoemulsification.
PURPOSE To describe the fluidic events that occur in a test chamber during phacoemulsification with longitudinal and torsional ultrasound (US) modalities. SETTING Pasteur Ophthalmic Clinic Phacodynamics Laboratory, Santiago, Chile, and Nanyang Technological University, Singapore. DESIGN Experimental study. METHODS Ultra-high-speed videos of a phacoemulsifying tip were recorded while the t...
متن کاملWound and surface temperatures in vivo in torsional and longitudinal modalities of ultrasound in coaxial microincisional cataract surgery
BACKGROUND To study phacoemulsification probe shaft/wound and corneal surface/tip temperatures in vivo during longitudinal, torsional and combined phacoemulsification modes and their relationship to machine parameters. DESIGN This was a prospective study at Chaithanya Eye Hospital and Research Institute, Trivandrum, India (tertiary). PARTICIPANTS Twenty-two eyes of 22 patients were randomiz...
متن کاملComparison of 45-degree Kelman and 45-degree balanced phaco tip designs in torsional microcoaxial phacoemulsification.
AIM To compare the intraoperative performance and postoperative outcome after microcoaxial torsional phacoemulsification using either a Kelman or balanced phaco tip. METHODS Cataracts were treated using 2.2 mm microcoaxial torsional phacoemulsification using either a 45-degree mini-flared Kelman(®) or a 45-degree Intrepid(®) Balanced phaco tip. Intraoperative measurements included total ultra...
متن کاملTips on getting the most from OZil
TORSIONAL phacoemulsification represents a clear advance on traditional lens extraction modalities due to its enhanced efficiency, ease of use and robust safety profile, according to a number of investigators. Speaking at the XXIV Congress of the ESCRS, several surgeons highlighted the benefits of using the OZil torsional handpiece (Alcon) in their cataract procedures and suggested it will even...
متن کامل