Effects of endogenous ascorbate on oxidation, oxygenation, and toxicokinetics of cell-free modified hemoglobin after exchange transfusion in rat and guinea pig.
نویسندگان
چکیده
Chemically modified hemoglobin (Hb) solutions are promising oxygen therapeutics; however, these agents are prone to intravascular oxidation. Using a 50% exchange transfusion (ET) model with bovine polymerized hemoglobin (PolyHbBv), we examined heme oxidation, oxygenation markers, and toxicokinetics in rats, an ascorbic acid (AA)-producing species, and in guinea pigs, a non-AA-producing species. Plasma AA decreased by 50% in guinea pigs after ET, but it was unchanged in rats for the first 20 h post-ET. Both species cleared PolyHbBv from the circulation at similar rates. However, exposure to ferric PolyHbBv over time was 5-fold greater in the guinea pig. Mass spectrometry analysis of plasma revealed oxidative modifications within the tetrameric fraction of PolyHbBv in guinea pig. Oxygen equilibrium curves of PolyHbBv measured in plasma after ET were more left-shifted in guinea pigs compared with rats, consistent with increased ferric PolyHbBv formation. Renal hypoxia-inducible factor (HIF)-1alpha, whose activity strictly depends on the partial pressure of oxygen increased over time, and it correlated inversely with circulating ferrous PolyHbBv in both species. Interestingly, HIF-1alpha activity was greater in guinea pigs compared with rats at 72 h post-ET. Mean arterial pressure increases were also greater in guinea pigs; however, minimal differences in cardiac and renal pathology were observed in either species. The present findings suggest the importance of plasma AA in maintaining the stability of acellular Hb susceptible to oxidation, and they may be relevant to humans, which display a similar plasma/tissue antioxidant status to guinea pig.
منابع مشابه
ENDOGENOUS RELEASE OF OPIATES BY REPETITIVE ELECTRICAL FIELD STIMULATION IN THE GUINEA-PIG AND RAT ILEAL LONGITUDINAL MUSCLE
The effect of repetitive electrical field stimulation and the response of the guinea-pig and rat ileal longitudinal muscle to single pulse stimulations was examined. Single pulse field stimulation produced twitch contraction which was inhibited by repetitive field stimulation (10 Hz, 40V, 0.5 msec for 5 m). This inhibition was largely, though never completely, reversed by naloxone. Contrac...
متن کاملThe Contribution of Water and Lipid Soluble Substances in the Relaxant Effects of Nigella sativa Extract on Guinea Pig Tracheal Smooth Muscle (in vitro)
Objective In previous studies, the relaxant, anticholinergic (functional antagonism), antihistaminic and its stimulatory effects on b-adrenoceptors of Nigella sativa have been demonstrated on guinea pig tracheal chains. In the present study, the relaxant effects of hydro-ethanolic, macerated aqueous (MA) and lipid-free macerated aqueous (LFMA) extract of Nigella sativa on tracheal chains of gu...
متن کاملP-100: Determination of The Proper Pregnancy Age for Collection and Culture of Guinea Pig Fetal Fibroblast
Background: Fibroblast cell lines have different application in biological research including nuclear transfer in cloning, feeder layer of embryonic stem cells, wound healing research and tissue engineering. The objective of the present study was to determine the proper pregnancy age for collecting and culturing guinea pig fetal fibroblast. Materials and Methods: Guinea pig fetuses were collect...
متن کاملDevelopment of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملDevelopment of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of pharmacology and experimental therapeutics
دوره 323 1 شماره
صفحات -
تاریخ انتشار 2007