PURPOSE The purpose of this study was to examine the feasibility of a fast protocol for whole-body diffusion-weighted imaging (WB-DWI) using a slice-accelerated echo-planar sequence, which, when using comparable image acquisition parameters, noticeably reduces measurement time compared to a conventional WB-DWI protocol. MATERIALS AND METHODS A single-shot echo-planar imaging sequence capable of simultaneous slice excitation and acquisition was optimized for WB-DWI on a 3 T MR scanner, with a comparable conventional WB-DWI protocol serving as the reference standard. Eight healthy individuals and one oncologic patient underwent WB-DWI. Quantitative analysis was carried out by measuring the apparent diffusion coefficient (ADC) and its coefficient of variation (CV) in different organs. Image quality was assessed qualitatively by two independent radiologists using a 4-point Likert scale. RESULTS Using our proposed protocol, the scan time of the WB-DWI measurement was reduced by up to 25.9 %. Both protocols, the slice-accelerated protocol and the conventional protocol, showed comparable image quality without statistically significant differences in the reader scores. Similarly, no significant differences of the ADC values of parenchymal organs were found, whereas ADC values of brain tissue were slightly higher in the slice-accelerated protocol. CONCLUSION It was demonstrated that slice-accelerated DWI can be applied to WB-DWI protocols with the potential to greatly reduce the required measurement time, thereby substantially increasing clinical applicability. KEY POINTS •Whole-body diffusion-weighted imaging (WB-DWI) using simultaneous multi-slice and blipped-CAIPIRINHA reduces the measurement time strongly without having a significant impact on image quality. •The reduction in measurement time might strongly contribute to the clinical applicability of WB-DWI. •However, further refinement of the slice-accelerated EPI sequence, and the WB-DWI protocol applying this sequence type seems necessary; and the value of such WB-DWI protocols for assessment of systemic oncological diseases needs to be investigated in further clinical studies.
منابع مشابه
Free-breathing cardiac DTI with simultaneous multi-slice excitation
free-breathing vs. single-slice sequential acquisitions (solid: mean angle, dashed: one standard deviation across the volume of interest). Fig. 1: Free breathing cardiac DTI sequence with additional 1D navigators, CAIPIRINHA blips and dual-band RF pulses. NAV 1 is repeated until acceptance, followed by NAV 2. 2808 Free-breathing cardiac DTI with simultaneous multi-slice excitation Constantin vo...
متن کاملUltra-fast MRI of the human brain with simultaneous multi-slice imaging.
The recent advancement of simultaneous multi-slice imaging using multiband excitation has dramatically reduced the scan time of the brain. The evolution of this parallel imaging technique began over a decade ago and through recent sequence improvements has reduced the acquisition time of multi-slice EPI by over ten fold. This technique has recently become extremely useful for (i) functional MRI...
متن کاملAccelerated Diffusion Tensor Imaging of Skeletal Muscle Using Simultaneous Multi-Slice Acquisition
Simultaneous multi-slice acquisition with CAIPIRINHA reduces the scan time in diffusion-weighted magnetic resonance imaging. In this article, we resume our early experience with this technique for accelerated diffusion tensor imaging of skeletal muscle [1].
متن کاملWideband MRI: A New Dimension of MR Image Acceleration
We propose a new paradigm of MRI acceleration using the frequency multiplexing technique in modern communication technology; we name it “Wideband MRI”. A major component of wideband MRI is frequency multiplexing of MR signals. Using simultaneous multi-slice RF excitation pulses centered at different frequencies followed by simultaneous multi-slice acquisition during readout, the total scan time...
متن کاملImproving diffusion MRI using simultaneous multi-slice echo planar imaging
In diffusion MRI, simultaneous multi-slice single-shot EPI acquisitions have the potential to increase the number of diffusion directions obtained per unit time, allowing more diffusion encoding in high angular resolution diffusion imaging (HARDI) acquisitions. Nonetheless, unaliasing simultaneously acquired, closely spaced slices with parallel imaging methods can be difficult, leading to high ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin
دوره 188 4 شماره
صفحات -
تاریخ انتشار 2016