Multifrequency inversion in magnetic resonance elastography.

نویسندگان

  • Sebastian Papazoglou
  • Sebastian Hirsch
  • Jürgen Braun
  • Ingolf Sack
چکیده

Time-harmonic shear wave elastography is capable of measuring viscoelastic parameters in living tissue. However, finite tissue boundaries and waveguide effects give rise to wave interferences which are not accounted for by standard elasticity reconstruction methods. Furthermore, the viscoelasticity of tissue causes dispersion of the complex shear modulus, rendering the recovered moduli frequency dependent. Therefore, we here propose the use of multifrequency wave data from magnetic resonance elastography (MRE) for solving the inverse problem of viscoelasticity reconstruction by an algebraic least-squares solution based on the springpot model. Advantages of the method are twofold: (i) amplitude nulls appearing in single-frequency standing wave patterns are mitigated and (ii) the dispersion of storage and loss modulus with drive frequency is taken into account by the inversion procedure, thereby avoiding subsequent model fitting. As a result, multifrequency inversion produces fewer artifacts in the viscoelastic parameter map than standard single-frequency parameter recovery and may thus support image-based viscoelasticity measurement. The feasibility of the method is demonstrated by simulated wave data and MRE experiments on a phantom and in vivo human brain. Implemented as a clinical method, multifrequency inversion may improve the diagnostic value of time-harmonic MRE in a large variety of applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution mechanical imaging of the human brain by three-dimensional multifrequency magnetic resonance elastography at 7T

Magnetic resonance elastography (MRE) is capable of measuring the viscoelastic properties of brain tissue in vivo. However, MRE is still limited in providing high-resolution maps of mechanical constants. We therefore introduce 3D multifrequency MRE (3DMMRE) at 7T magnetic field strength combined with enhanced multifrequency dual elasto-visco (MDEV) inversion in order to achieve high-resolution ...

متن کامل

In vivo multifrequency magnetic resonance elastography of the human intervertebral disk.

PURPOSE To test in vivo magnetic resonance elastography (MRE) of the human intervertebral disk (IVD). METHODS The feasibility of MRE in IVD was demonstrated in ex vivo bovine disks. Sixteen asymptomatic volunteers underwent multifrequency MRE of the lumbar spine (IVD L3/4 and L4/5, n = 32) using a posterior plate transducer connected to a loudspeaker and operated at five frequencies from 50 t...

متن کامل

MR elastography of the liver and the spleen using a piezoelectric driver, single-shot wave-field acquisition, and multifrequency dual parameter reconstruction.

PURPOSE Viscoelastic properties of the liver are sensitive to fibrosis. This study proposes several modifications to existing magnetic resonance elastography (MRE) techniques to improve the accuracy of abdominal MRE. METHODS The proposed method comprises the following steps: (i) wave generation by a nonmagnetic, piezoelectric driver suitable for integration into the patient table, (ii) fast s...

متن کامل

High-Resolution Mechanical Imaging of Glioblastoma by Multifrequency Magnetic Resonance Elastography

OBJECTIVE To generate high-resolution maps of the viscoelastic properties of human brain parenchyma for presurgical quantitative assessment in glioblastoma (GB). METHODS Twenty-two GB patients underwent routine presurgical work-up supplemented by additional multifrequency magnetic resonance elastography. Two three-dimensional viscoelastic parameter maps, magnitude |G*|, and phase angle φ of t...

متن کامل

Analysis of liver viscosity behavior as a function of multifrequency magnetic resonance elastography (MMRE) postprocessing.

PURPOSE To analyze the relevance of the viscosity measurement as a liver diagnostic marker. MATERIALS AND METHODS To determine the level of fibrosis, a Fibroscan test was performed on 40 subjects (10 healthy volunteers and 30 patients). Subsequently, multifrequency magnetic resonance elastography (MMRE) tests were made with a pneumatic driver at 60, 70, and 80 Hz. Phase images were analyzed w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 57 8  شماره 

صفحات  -

تاریخ انتشار 2012