Harmonic Planning Levels for Australian Distribution Systems
نویسندگان
چکیده
A modelling technique is developed for determining the harmonic voltage distribution across a distribution system when there is an equitable distribution of harmonic emission. The harmonic voltages at the 132kV and 415V levels are fixed to values based on IEC Compatibility and Planning Levels and the intermediate voltages determined. Studies are made of six systems, typical of Australian distribution practice, to examine the effect of choice of voltage level and system parameters over the harmonic range of 2-40. Based on the study, harmonic Planning Levels are recommended for application to Australian distribution systems.
منابع مشابه
Dynamic Harmonic Modeling and Analysis of VSC-HVDC Systems
Harmonics have become an important issue in modern power systems. The widespread penetration of non-linear loads to emerging power systems has turned power quality analysis into an important operation issue under both steady state and transient conditions. This paper employs a Dynamic Harmonic Domain (DHD) based framework for dynamic harmonic analysis of VSC-HVDC systems. These systems are wide...
متن کاملA graph search algorithm: Optimal placement of passive harmonic filters in a power system
The harmonic in distribution systems becomes an important problem due to an increase in nonlinear loads. This paper presents a new approach based on a graph algorithm for optimum placement of passive harmonic filters in a multi-bus system, which suffers from harmonic current sources. The objective of this paper is to minimize the network loss, the cost of the filter and the total harmonic disto...
متن کاملA study on the identification of major harmonic sources in power systems
Power system transmission and distribution utilities strive to ensure that the voltage harmonic distortion planning levels are maintained by limiting the harmonic currents injected by the loads. With large customers assessment of the harmonics contributed is carried out at the point of common coupling (PCC). Determination of the contribution to the overall harmonic distortion at the PCC by the ...
متن کاملDynamic Compensation of Electrical Power Systems Using Multilevel Voltage Source Inverter
A New Static Var Generator (SVG), using cascaded full-bridge inverters (FBI) with binary output levels and the parallel connections of two cascaded inverters by means of current sharing reactor in each phases is introduced. The new M-level inverter, where M is 2n+2 - 3, consists of only 2n single-phase full bridges for each phases. The proposed technique not only increases the current capacity ...
متن کاملSolving Harmonic Resonance Problems on the Medium Voltage System
Harmonic problems are increasing on MV systems, especially with the application of power factor correction capacitors or extensive underground networks that resulting resonances close to the fifth harmonic. This paper describes two case studies of solving harmonic resonance problems on distribution systems with the design of harmonic filters that provide both power factor correction and harmoni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003