Evaluation of sympathetic nerve terminals with [(11)C]epinephrine and [(11)C]hydroxyephedrine and positron emission tomography.

نویسندگان

  • G Münch
  • N T Nguyen
  • S Nekolla
  • S Ziegler
  • O Muzik
  • P Chakraborty
  • D M Wieland
  • M Schwaiger
چکیده

BACKGROUND The goal of the present study was to directly compare the new radiopharmaceutical agent [(11)C]epinephrine (EPI) with [(11)C]hydroxyephedrine (HED) through the use of PET. METHODS AND RESULTS Seven healthy volunteers and 10 patients were investigated after heart transplantation. PET images of both tracers were of excellent quality in the volunteers. Values for radiolabeled metabolites (measured in percent of blood activity) at 5, 20, and 60 minutes after injection were approximately 35%, approximately 82%, and approximately 86% for EPI and approximately 13%, approximately 47%, and approximately 78% for HED, respectively. At 35 minutes, metabolite-corrected mean myocardial retention fraction of EPI (0. 235+/-0.022 min(-1)) was significantly greater (P<0.01) than that of HED (0.142+/-0.012 min(-1)). Corrected tracer retention fractions of both EPI and HED were significantly reduced in transplant recipients (0.055+/-0.004 min(-1), P<0.0001; and 0.050+/-0.006 min(-1), P<0. 0001, respectively) compared with volunteers. Normalization of retention fractions of patients with transplantation within 1 year to volunteers resulted in a value (ratio expressed in percent) of 20. 6+/-1.8% for EPI, significantly (P<0.03) smaller than 27.8+/-0.8% for HED. In patients with transplantation later than 1 year, the values were 26.0+/-2.9% for EPI compared with 44.2+/-5.6% for HED (P<0.014). CONCLUSIONS Both tracers showed high selectivity for neuronal uptake in the heart, with a significant reduction in tracer retention in transplant recipients compared with volunteers. Compared with HED, EPI showed greater retention in volunteers and a lower retention ratio in transplant recipients, suggesting that EPI may be the superior tracer with higher sensitivity to neuronal abnormalities. Because EPI reflects neuronal uptake, metabolism, and storage, it may be more suitable for the study of neuronal integrity than HED, which primarily traces uptake-1 capacity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between altered sympathetic innervation, oxidative metabolism and contractile function in the cardiomyopathic human heart; a non-invasive study using positron emission tomography.

AIMS To identify functional and metabolic correlates of impaired presynaptic sympathetic innervation in the cardiomyopathic human heart using non-invasive correlative imaging. METHODS AND RESULTS In 10 patients with idiopathic dilated cardiomyopathy, presynaptic catecholamine uptake sites were quantified by positron emission tomography with C-11 hydroxyephedrine. Oxidative metabolism was meas...

متن کامل

Scintigraphic pattern of regional cardiac sympathetic innervation in patients with familial long QT syndrome using positron emission tomography.

BACKGROUND The purpose of this study was to determine whether scintigraphic evidence of cardiac sympathetic neuronal dysinnervation is present in patients with the familial long QT syndrome. The "sympathetic imbalance" hypothesis for the familial long QT syndrome proposes that the long QT syndrome results from a congenital imbalance of sympathetic innervation of the heart caused by lower-than-n...

متن کامل

Iodine-123 metaiodobenzylguanidine imaging and carbon-11 hydroxyephedrine positron emission tomography compared in patients with left ventricular dysfunction.

BACKGROUND Although both (123)I-metaiodobenzylguanidine ((123)I-MIBG) imaging and (11)C-hydroxyephedrine ((11)C-HED) positron emission tomography (PET) are used for assessing cardiac sympathetic innervation, their relationship remains unknown. The aims were to determine whether (123)I-MIBG parameters such as heart-to-mediastinum ratio (H/M) are associated with quantitative measures by (11)C-HED...

متن کامل

Prediction of all-cause death using 11C-hydroxyephedrine positron emission tomography in Japanese patients with left ventricular dysfunction

OBJECTIVES The aim of this study was to determine whether (11)C-hydroxyephedrine ((11)C-HED) can predict adverse events including all-cause death in Japanese patients with left ventricular (LV) dysfunction. BACKGROUND Although (11)C-HED PET has been used to assess cardiac sympathetic innervation in various disease conditions, data on their prognostic value are limited. METHODS Sixty patient...

متن کامل

Evidence for regional catecholamine uptake and storage sites in the transplanted human heart by positron emission tomography.

Positron emission tomography in combination with the newly introduced catecholamine analogue [11C]hydroxyephedrine ([11C]HED) enables the noninvasive delineation of sympathetic nerve terminals of the heart. To address the ongoing controversy over possible reinnervation of the human transplant, 5 healthy control subjects and 11 patients were studied after cardiac transplant by this imaging appro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 101 5  شماره 

صفحات  -

تاریخ انتشار 2000