Experimental study on nonuniformity of line jitter in CCD images.

نویسندگان

  • G Luo
  • O Chutatape
  • H Fang
چکیده

The line jitter of CCD images can considerably influence the precision and resolution of a high-accuracy vision-based automated inspection system. We report the experimental studies on the line jitter of CCD images. By use of a method of Harr wavelet transform, correlation, and statistics analysis to detect the line jitter of subpixels, the experiment reveals that the line jitter exhibits inherent nonuniformity and that different CCD cameras have different jitter characteristics. It was commonly thought that the jitter could be eliminated by detection of the jitter level and performing compensation. However, the nonuniformity revealed in the experiment makes jitter compensation much harder.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs

Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...

متن کامل

Development of a Protocol for CCD Calibration: Application to a Multispectral Imaging System

In this paper we describe in detail a method for calibrating a CCD-based camera. The calibration aims to remove both temporal and systematic noises introduced by the sensor, electronics, and optics after which we can correct the non-linearity of its response. For the non-linearity correction we use a simple and powerful approach consisting on a complementary approach between a polynomial fittin...

متن کامل

Framework of Jitter Detection and Compensation for High Resolution Satellites

Attitude jitter is a common phenomenon in the application of high resolution satellites, which may result in large errors of geo-positioning and mapping accuracy. Therefore, it is critical to detect and compensate attitude jitter to explore the full geometric potential of high resolution satellites. In this paper, a framework of jitter detection and compensation for high resolution satellites i...

متن کامل

Co-registration of Chang’e-1 Stereo Images and Laser Altimeter Data for 3d Mapping of Lunar Surface

This paper presents a method for co-registration of Chang’E-1 lunar orbiter stereo images and laser altimeter (LAM) data for 3D mapping of lunar surface. First, a digital elevation model (DEM) is automatically generated from the three-line CCD stereo images based on rigorous pushbroom sensor model and multi-level image matching. The DEM is then registered to LAM data through surface matching wi...

متن کامل

In-orbit Calibration Method Based on Empirical Model for Non-collinear TDI CCD Camera

An empirical model is proposed to solve the problem that exists in in-orbit calibration method for TDICCD camera in this paper. The method brings in the line frequency normalization and virtual image stitching from TDICCD images to the preprocessing procedure, which makes the virtual mosaic images has the same characteristics as the regular Linear push-broom CCD images, therefore the interior a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 40 26  شماره 

صفحات  -

تاریخ انتشار 2001