Hemodynamic Consequences of Laparoscopy for Patients on Mechanical Circulatory Support.

نویسندگان

  • Heidi Reich
  • Danny Ramzy
  • Lawrence Czer
  • Fardad Esmailian
  • Jaime Moriguchi
  • Kai Ihnken
  • Taizoon Yusufali
  • Nicola D'Attellis
  • Francisco Arabia
  • Alagappan Annamalai
چکیده

BACKGROUND Technologic advances and superior survival with mechanical circulatory support (MCS) have led to an expanding population that develops intraabdominal conditions requiring intervention. Whether laparoscopy can be performed without detrimental effects on hemodynamics and device function is not well described. MATERIALS AND METHODS Effects of laparoscopy performed on MCS were retrospectively assessed. Intraoperative hemodynamics and device function were compared with the same time interval 24 hours prior to surgery using intrapatient paired t tests. Outcomes included survival, transfusion, thromboembolic events, and infection. RESULTS Twelve patients with ventricular assist devices or total artificial hearts underwent laparoscopy from 2012 to 2014. Median follow-up was 116 days. Operations included cholecystectomy, diagnostic laparoscopy, gastrojejunostomy, and gastrostomy. There were no differences between preoperative and intraoperative mean arterial pressure, heart rate, and inotrope or vasopressor requirements (P > .05). Device fill volume, flow, rate, and power were unchanged (P > .05), whereas pulsatility index decreased by 0.2 (95% confidence interval, 0.03, 0.36) with laparoscopy (P = .03). All intraoperative fluctuations in hemodynamics and device function improved with reduction of pneumoperitoneum, adjusting device speed, or pharmacologic support. There were no operative mortalities. Thirty-day survival and survival to discharge were 75% and 50%, respectively. Despite antiplatelet therapy and preoperative international normalization ratio of 2.2 ± 0.9, there were no re-operations for bleeding, and 50% did not require transfusion. Two patients with recent cardiac surgery had thromboembolic events: one stroke and one device thrombus. None had postoperative bacteremia or driveline infection. CONCLUSIONS Laparoscopy can be performed on MCS with low morbidity and mortality and minimal perturbations in hemodynamics and device function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Practical Approach to Mechanical Circulatory Support in Patients Undergoing Percutaneous Coronary Intervention: An Interventional Perspective.

Percutaneous mechanical circulatory support has been used to stabilize patients in cardiogenic shock and provide hemodynamic support during high-risk percutaneous coronary interventions for several decades. The goal of this paper is to provide a practical approach to percutaneous mechanical circulatory support in patients undergoing percutaneous coronary intervention with cardiogenic shock and/...

متن کامل

Avoiding hemodynamic collapse during high-risk percutaneous coronary intervention: Advanced hemodynamics of impella support.

The rate of performing primary percutaneous coronary intervention in patients with complex coronary artery disease is increasing. The use of percutaneous mechanical circulatory support devices provides critical periprocedural hemodynamic support. Mechanical support has increased the safety and efficacy of interventional procedures in this high-risk patient population. Predicting patient respons...

متن کامل

Biventricular Mechanical Circulatory Support Does Not Prevent Delayed Myocardial Ventricular Rupture following Myocardial Infarction

Cardiogenic shock and myocardial rupture can complicate an acute myocardial infarction (AMI). A case is reported in which a 58-year-old male with an acute inferior myocardial infarction required placement of biventricular assist device for hemodynamic support eight days after the onset of his AMI; eleven days after his AMI, the patient developed abrupt onset of hemodynamic instability with mass...

متن کامل

Hemodynamic Transesophageal Echocardiography-Guided Venous-Arterial Extracorporeal Membrane Oxygenation Support in a Case of Giant Cell Myocarditis

Giant cell myocarditis (GCM) is a rare and commonly fatal form of fulminant myocarditis. During the acute phase, while immunosuppressive therapy is initiated, venoarterial extracorporeal membrane oxygenation (VA-ECMO) support is commonly used as a bridge to heart transplantation or recovery. Until recently, conventional transesophageal echocardiography and transthoracic echocardiography were th...

متن کامل

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of laparoendoscopic & advanced surgical techniques. Part A

دوره 25 12  شماره 

صفحات  -

تاریخ انتشار 2015