Combined PET and low-dose, noncontrast CT scanning obviates the need for additional diagnostic contrast-enhanced CT scans in patients undergoing staging or restaging for lymphoma.

نویسندگان

  • R L Elstrom
  • J P Leonard
  • M Coleman
  • R K J Brown
چکیده

BACKGROUND Positron emission tomography (PET) is more accurate than computed tomography (CT) in staging and restaging of lymphoma, but both are considered necessary. Increasingly, PET is carried out with a low-dose CT scan. Many patients undergo both PET/CT and standard diagnostic CT. The clinical utility of performing both studies in patients with lymphoma was evaluated. PATIENTS AND METHODS Patients with lymphoma who underwent concurrent PET/CT and diagnostic CT (a scan pair) were identified, and findings detected in either scan but not both were documented. Discrepancies were considered significant if they were related to either lymphoma or another disease process which potentially required intervention. RESULTS Eighty-seven scan pairs were identified. PET/CT detected additional lesions over diagnostic CT in 30 patients, of which 11 demonstrated increased clinical stage. Lymphoma therapy changed based on PET/CT in two patients, and one occult rectal cancer was detected. In contrast, diagnostic CT detected five relevant findings, including two incidental findings (venous thrombosis) and three patients with splenic lesions, none of which could be confirmed as lymphoma. No patient had change of stage or lymphoma therapy based on diagnostic CT. CONCLUSION In our series, diagnostic CT did not add value to staging or restaging of lymphoma when carried out concurrently with PET/CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-Hodgkin lymphoma and Hodgkin disease: coregistered FDG PET and CT at staging and restaging--do we need contrast-enhanced CT?

PURPOSE To retrospectively compare diagnostic value of coregistered fluorine 18 fluorodeoxyglucose positron emission tomographic (PET) and computed tomographic (CT) scans obtained with low-dose nonenhanced CT (PET/CT) with those routinely obtained with contrast material-enhanced CT for staging and restaging of disease in patients with Hodgkin disease or high-grade non-Hodgkin lymphoma. MATERI...

متن کامل

Rare ocular and skin lesions of Marginal Zone Lymphoma detected by 18F-FDG PET/CT

We report a case of a 75-year old man that came at hematologist’s attention for lymphoma evaluation due to axillary lymph node enlargement and fever. Thorax, abdomen and pelvis Contrast-Enhanced Computed Tomography (CECT) showed lymph nodes, spleen and liver lesions. Axillary lymph node biopsy was performed and the diagnosis of marginal zone lymphoma (MZL) at stage IV was postulated, then the p...

متن کامل

Diagnostic Value of Software-Based Image Fusion of Computed Tomography and F18-FDG PET Scans in Patients with Malignant Lymphoma

AIM The purpose of this study was to evaluate the accuracy of 2-deoxy-2-[fluorine-18]fluoro-D-glucose (FDG) positron emission tomography (PET), computed tomography (CT), and software-based image fusion of both modalities in the imaging of non-Hodgkin's lymphoma (NHL) and Hodgkin's disease (HD). METHODS 77 patients with NHL (n = 58) or HD (n = 19) underwent a FDG PET scan, a contrast-enhanced ...

متن کامل

Whole-body FDG-PET imaging for staging of Hodgkin's disease and lymphoma.

UNLABELLED Accurate staging of Hodgkin's disease (HD) and non-Hodgkin's lymphoma (NHL) is important for treatment management. In this study, the utility of 2-[18F]fluoro-2-deoxy-D-glucose (FDG) whole-body PET was evaluated as an imaging modality for initial staging or restaging of 7 HD and 11 NHL patients. METHODS Whole-body PET-based staging results were compared to the patient's clinical st...

متن کامل

Is contrast material needed after treatment of malignant lymphoma in positron emission tomography/computed tomography?

PURPOSE Positron emission tomography (PET)/computed tomography (CT) with (18)F-fluorodeoxyglucose is widely used for post-therapeutic surveillance of malignant lymphoma. Debate still exists as to whether intravenous contrast media during the CT stage of a PET/CT scan should be used. The purpose of this study was to investigate the clinical value of contrast agent in PET/CT in patients with lymp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of oncology : official journal of the European Society for Medical Oncology

دوره 19 10  شماره 

صفحات  -

تاریخ انتشار 2008