Separation of monomethyl-benz[a]anthracene isomers using cyclodextrin-modified electrokinetic chromatography.
نویسندگان
چکیده
Cyclodextrin-modified electrokinetic chromatography (CD-EKC) was investigated for the separation of 12 monomethylbenz[a]anthracene (MBA) isomers. Combined use of a polymeric surfactant, poly(sodium 10-undecenyl sulfate) (poly-SUS), with various types of neutral cyclodextrins (CDs) [beta-CD, gamma-CD, dimethyl-beta-CD (DM-beta-CD), trimethyl-beta-CD (TM-beta-CD) and hydroxypropyl-beta-CD (HP-beta-CD)] were successful in CD-EKC separation of the MBA isomers. Baseline resolution of 10 of the 12 isomers, except for 9-MBA and 2-MBA, was achieved with gamma-CD at pH 9.75. The beta-CD, gamma-CD, and beta-CD derivatives (DM-beta-CD, TM-beta-CD, HP-beta-CD) were found to have different resolution and selectivity. Additionally, the tR/t0 values of isomers were found to be dependent on the type and concentration of the CD additives. In general, tR/t0 values of MBA isomers decrease with an increase in the concentration of beta-CD derivatives, whereas the reversed was true when the concentrations of native beta-CD and gamma-CD were varied. The combination of 5 mM gamma-CD, 0.5% (w/v) poly-SUS, 35% (v/v) acetonitrile at a pH of 9.75 provided the best selectivity and resolution of the MBA isomers with a separation time of 110 min. However, the use of 30 mM DM-beta-CD under similar EKC conditions resulted in much faster separation (ca. 16 min) of 10 MBA isomers.
منابع مشابه
Electrokinetic chromatography of twelve monomethylbenz[a]anthracene isomers using a polymerized anionic surfactant.
A method for the separation of twelve monomethyl-substituted benz[a]anthracene isomers using poly-(sodium undecylenic sulfate) (poly-SUS) surfactant by means of electrokinetic capillary chromatography (EKC) is described. Several parameters such as concentration of acetonitrile (ACN), pH, as well as applied voltage were studied to optimize the EKC separation. ACN at a concentration of 35% v/v, 1...
متن کاملChiral separation of sertraline with microemulsion electrokinetic chromatography on a polymer/β-cyclodextrin assembling molecular film modified capillary.
A capillary modified by assembling a molecular film was presented for the chiral separation of sertraline by microemulsion electrokinetic chromatography. The assembling molecular film was constructed with poly(diallyldimethylammonium-chloride) and β-cyclodextrin via inclusion complexation. The separation efficiency of cis-trans isomers and enantiomers of sertraline was improved with a running m...
متن کاملSeparation of 1,4-benzodiazepine Derivates by Cyclodextrin Modified Micellar Electrokinetic Chromatography
The electrophoretic separation of electrically neutral benzodiazepines (BZDs) can be achieved by micellar electrokinetic chromatograpy (MEKC). The cyclodextrin (CD)-modified micellar electrokinetic chromatography separation of eight of the most frequently used BZD was obtained within 15 minutes at + 25 kV on a 64.5 cm x 50 μm I.D. silica capillary at 25C, using a 25 mM sodium tetraborate-50 mM ...
متن کاملChiral separation of vinpocetine using cyclodextrin-modified micellar electrokinetic chromatography.
A cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) technique has been developed for enantioseparation of vinpocetine using an inexpensive 2-hydroxypropyl-β-CD (HP-β-CD) as the chiral selector (CS). The best chiral separation was achieved using 40 mM HP-β-CD as the CS in 50 mM phosphate buffer (pH 7.0) consisting of 40 mM sodium dodecyl sulfate (SDS) at a separation tempera...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 910 1 شماره
صفحات -
تاریخ انتشار 2001