Progress in two-dimensional arrays for real-time volumetric imaging.
نویسندگان
چکیده
The design, fabrication, and evaluation of two dimensional array transducers for real-time volumetric imaging are described. The transducers we have previously described operated at frequencies below 3 MHz and were unwieldy to the operator because of the interconnect schemes used in connecting to the transducer handle. Several new transducers have been developed using new connection technology. A 40 x 40 = 1,600 element, 3.5 MHz array was fabricated with 256 transmit and 256 receive elements. A 60 x 60 = 3,600 element 5.0 MHz array was constructed with 248 transmit and 256 receive elements. An 80 x 80 = 6,400 element, 2.5 MHz array was fabricated with 256 transmit and 208receive elements. 2-D transducer arrays were also developed for volumetric scanning in an intra cardiac catheter, a 10 x 10 = 100 element 5.0 MHz forward-looking array and an 11 x 13 = 143 element 5.0 MHz side-scanning array. The-6dB fractional bandwidths for the different arrays varied from 50% to 63%, and the 50 omega insertion loss for all the transducers was about-64 dB. The transducers were used to generate real-time volumetric images in phantoms and in vivo using the Duke University real time volumetric imaging system, which is capable of generating multiple planes at any desired angle and depth within the pyramidal volume.
منابع مشابه
A high frequency amplitude-steered array for real-time volumetric imaging.
Real-time three-dimensional acoustic imaging is difficult in water or tissue because of the slow speed of sound in these media. Conventional pulse-echo data collection, which uses at least one transmit pulse per line in the image, does not allow for the real-time update of a volume of data at practical ranges. Recently, a linear amplitude-steered array was presented that allows the collection o...
متن کاملA Three-Dimensional Pattern-Space Representation for Volumetric Arrays
A three-dimensional pattern-space representation is presented for volumetric arrays. In this representation, the radiation pattern of an array is formed by the evaluation of the three-dimensional pattern-space on a spherical surface. The scan angle of the array determines the position of this surface within the pattern-space. This pattern-space representation is used in conjunction with a genet...
متن کاملSU-F-BRCD-01: A Novel Dual Source Array Tetrahedron Beam Computed Tomography (TBCT) System for Image Guided Radiotherapy.
PURPOSE To design and test the feasibility of a novel dual source array, dual detector array TBCT system which is capable of both volumetric CT imaging as well as real-time stereoscopic x-ray imaging for image guided radiotherapy (IGRT). METHODS Besides producing improved image quality, the geometry of TBCT is also more compact and flexible. It is possible to mount two x-ray source arrays and...
متن کاملThree-dimensional Volumetric Ultrasonography of Enlarged Adrenal Gland in Dog
Objective: Detection and evaluation of adrenal glands are complex problems in conventional ultrasonography in dogs. Using three-dimensional (3D) ultrasonography (US) in adrenal gland volume evaluation can add new potential for further adrenal studies. Design: Descriptive study Animals: a total of 10 mix breed dogs Procedures: The dogs underwent two dimensional (2D) and 3D US of the adrenal g...
متن کاملA Miniature Real-Time Volumetric Ultrasound Imaging System
Progress made in the development of a miniature real-time volumetric ultrasound imaging system is presented. This system is targeted for use in a 5-mm endoscopic channel and will provide real-time, 30-mm deep, volumetric images. It is being developed as a clinically useful device, to demonstrate a means of integrating the front-end electronics with the transducer array, and to demonstrate the a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasonic imaging
دوره 20 1 شماره
صفحات -
تاریخ انتشار 1998