Coarctation of the aorta associated with patent ductus arteriosus.

نویسندگان

  • H B BURCHELL
  • O T CLAGETT
  • J C COOLEY
  • J D DUSHANE
  • J W KIRKLIN
  • E H WOOD
چکیده

The combination of patent (luctus arteriosus land coarctation of the aorta poses special anatomic, physiologic and surgical proldems. An experience with 14 such cases is presented, wVhich suggests that pulmonary hypertension occurs frequently in these cases. Physiologic data in cases having coarctation of the aorta, patent (luctus arteriosus and pulmonary hypertension that underwent cardiac catheterization are preselnte(l. Clinical, anatoimic, physiologic ani(l surgictal implications of this combination are discussedl.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

( Joarctation of the Aorta Associated with Patent Ductus Arteriosus

The combination of patent (luctus arteriosus land coarctation of the aorta poses special anatomic, physiologic and surgical proldems. An experience with 14 such cases is presented, wVhich suggests that pulmonary hypertension occurs frequently in these cases. Physiologic data in cases having coarctation of the aorta, patent (luctus arteriosus and pulmonary hypertension that underwent cardiac cat...

متن کامل

A Rare Case of Acyanotic Congenital Heart Disease, Large Patent Ductus Arteriosus with Pre-ductal Coarctation of Descending Thoracic Aorta with Patent Ductus Arteriosus Closure and Extra Anatomical Bypass Grafting

We report a case of 18-year-old female patient with large patent ductus arteriosus (PDA)-preductal coarctation of descending thoracic aorta. She underwent large PDA closure with a prosthetic graft from ascending aorta to descending thoracic aorta by mid-sternotomy on cardiopulmonary bypass machine under total hypothermic circulatory arrest.

متن کامل

Successful transcatheter balloon dilatation of coarctation of aorta and coil occlusion of patent ductus arteriosus in a single catheterization procedure.

Simultaneous transcatheter coil occlusion of patent ductus arteriosus and balloon angioplasty of coarctation of aorta is avoided since intimal tearing after angioplasty is believed to increase the risk for dissection of the aorta during catheter manipulation. We report a 14-month-old boy, with weight of 7.6 kg, with aortic coarctation and patent ductus arteriosus with a large left-to-right shun...

متن کامل

Usefulness of endovascular stent-graft for combination with a strict aort coarctation and patent ductus arteriosus for an adult patient: a case report

We reported a 21-year-old patient with strict descending aorta coarctation and small post-ductal patent ductus arteriosus, complicated with abortion and hypertension. The patient was successfully treated by endovascular stent-graft with a single cardiac catheterization. Endovascular stent-graft is an easy, safe, and reliable intervention for the treatment of strict descending aorta coarctation ...

متن کامل

COOLEY AND CO - WORKERS TABLE 1 . - Clinical Data on 6 Patients with Coarctation of the Aorta , Patent Ductus Arteriosus , and Pulmonary Hypertension Case

The combination of patent (luctus arteriosus land coarctation of the aorta poses special anatomic, physiologic and surgical proldems. An experience with 14 such cases is presented, wVhich suggests that pulmonary hypertension occurs frequently in these cases. Physiologic data in cases having coarctation of the aorta, patent (luctus arteriosus and pulmonary hypertension that underwent cardiac cat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 13 6  شماره 

صفحات  -

تاریخ انتشار 1956