Banding hemorrhoids using the O'Regan Disposable Bander. Single center experience.

نویسندگان

  • Dimitrios Paikos
  • Anthie Gatopoulou
  • John Moschos
  • Anastasios Koulaouzidis
  • Shivram Bhat
  • Dimitrios Tzilves
  • Konstantinos Soufleris
  • Dimitrios Tragiannidis
  • Ioannis Katsos
  • Anestis Tarpagos
چکیده

BACKGROUND Hemorrhoids are the most common anorectal disorder in the Western World and are a major cause of active, relapsing or chronic rectal bleeding. Many treatment options have been proposed and tried for early-stage hemorrhoids. There is general agreement that rubber banding ligation (RBL) is safe and effective. AIMS To evaluate the effectiveness and complications associated with RBL performed in outpatients for symptomatic hemorrhoids using the O'Regan Disposable Bander device. RESULTS Sixty consecutive patients underwent hemorrhoid banding with the O'Regan Disposable Bander. The mean time required for one session was 6.2 min; the longest was 10 min. No major complications were noted. Minor early and late bleeding was reported in 10% and 6.7% respectively, but none was severe. Pain occurred in 6.7% but was not severe. In all cases, clinical and endoscopic (range and form scores) improvement was observed and patients of all ages, including the elderly, were found to be tolerant to the procedure. CONCLUSION RBL performed in outpatients for symptomatic hemorrhoids using the O'Regan Disposable Bander device is associated with a good response and low complication rate. We recommend the technique as a safe and reliable treatment option.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Definitive therapy for internal hemorrhoids--new opportunities and options.

Hemorrhoids are common in Western societies. Appropriate assessment and treatment of symptomatic hemorrhoids can substantially reduce morbidity and improve patient well-being. In this article, the clinical presentation, differential diagnoses, and current treatment options, including the CRH-O'Regan banding device, an emerging technology for the anoscopic treatment of symptomatic internal hemor...

متن کامل

Stapled Hemorrhoidopexy and Long Term Outcomes - A Single Center Experience of 3130 Cases at Healing Hands Clinic, India

Hemorrhoids are one of the commonly reported anorectal disorders and a worldwide problem. It has prevalence rate of 4.4% in the United States [1]. However; no epidemiological data is available for India, but considered to be higher in Indian population. Most of the patients who turned up late to the hospitals, presented with advanced disease (Grade III or IV). The treatment options for hemorrho...

متن کامل

Evaluation of Chromosomal Aberrations Among Radiotherapy Staff in the City of Tehran Because of Occupational Exposure Using Micronucleus Assay and GTG-Banding

Introduction: Exposure to ionizing radiation as a result of diagnostic, treatment and occupational reasons, has created a remarkable range of cytogenetic damage in the DNA, as the first and main goal of ionizing radiation. The aim of this study is to assess the chromosomal damage in medical radiotherapy workers and its association with effective parameters such as age, sex, duration of employme...

متن کامل

Rubber band ligation of hemorrhoids: A guide for complications

Rubber band ligation is one of the most important, cost-effective and commonly used treatments for internal hemorrhoids. Different technical approaches were developed mainly to improve efficacy and safety. The technique can be employed using an endoscope with forward-view or retroflexion or without an endoscope, using a suction elastic band ligator or a forceps ligator. Single or multiple ligat...

متن کامل

Electrochemical Determination of Neonicotinoid Insecticide Clothianidin by Nanomaterial based Disposable Electrode

Disposable, selective and low-cost carbon nanotube modified electrodes were fabricated for the electrochemical detection of neonicotinoid insecticide, Clothianidin (CLT). Almost 2 folds’ increase at Clothianidin reduction signal was obtained by using single-walled carbon nanotube modified electrodes (SWCNT-PGE) compared to unmodified electrodes. These nanomaterials modified electrodes developed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of gastrointestinal and liver diseases : JGLD

دوره 16 2  شماره 

صفحات  -

تاریخ انتشار 2007