Guide for interpreting reports from inspections/investigations of indoor mold.

نویسندگان

  • W Elliott Horner
  • Charles Barnes
  • Rosa Codina
  • Estelle Levetin
چکیده

Inspections and testing of indoor environments for mold growth increased dramatically in the past decade. Allergists can now be presented copies of reports and laboratory data and asked to provide an interpretation, although allergists are seldom trained to review environmental data. There is no single sampling method that is both specific for mold growth and robust enough to reliably detect mold growth. There is no standard method for these inspections or testing and no widely recognized credential for investigators, and therefore reports also vary in quality, objectives, and thoroughness. Despite these issues, observations from informed inspections coupled with results from qualified analyses of samples that are collected with a useful strategy can usually indicate whether mold growth is present in a building, but the nature of the report should be assessed before any interpretation of the results and data are attempted. This rostrum discusses objectives of inspections, describes qualifications for investigators, outlines the limitations of various sampling methods applicable to mold and to some degree endotoxin, and provides guidance for data interpretation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Occurrence of moisture problems in schools in three countries from different climatic regions of Europe based on questionnaires and building inspections - the HITEA study.

UNLABELLED The aim of this study was to assess occurrence of dampness and mold in school buildings in three European countries (the Netherlands, Spain, and Finland), representing different climatic regions. An assessment was performed utilizing both questionnaires and on-site building investigations, and the agreement between these two methods was evaluated for validation purposes. On the basis...

متن کامل

Indoor mold, toxigenic fungi, and Stachybotrys chartarum: infectious disease perspective.

Damp buildings often have a moldy smell or obvious mold growth; some molds are human pathogens. This has caused concern regarding health effects of moldy indoor environments and has resulted in many studies of moisture- and mold-damaged buildings. Recently, there have been reports of severe illness as a result of indoor mold exposure, particularly due to Stachybotrys chartarum. While many autho...

متن کامل

Respiratory and Allergic Health Effects of Dampness, Mold, and Dampness-Related Agents: A Review of the Epidemiologic Evidence

OBJECTIVES Many studies have shown consistent associations between evident indoor dampness or mold and respiratory or allergic health effects, but causal links remain unclear. Findings on measured microbiologic factors have received little review. We conducted an updated, comprehensive review on these topics. DATA SOURCES We reviewed eligible peer-reviewed epidemiologic studies or quantitativ...

متن کامل

Health effects of mycotoxins in indoor air: a critical review.

Industrial hygienists (IHs) are called upon to investigate exposures to mold in indoor environments, both residential and commercial. Because exposure standards for molds or mycotoxins do not exist, it is important for the industrial hygienist to have a broad knowledge of the potential for exposure and health effects associated with mold in the indoor environment. This review focuses on the tox...

متن کامل

Health-based Risk Assessment for Exposure to Airborne Mold in Residential Propertie3s

With reference to mold investigations, the three primary tasks of the Indoor Environmental Professional (IEP) may be described as encompassing an exposure assessment, a risk assessment, and risk management. The focus of the inspection may be on determining if the structure is contaminated [exposure assessment], if the occupants are potentially at risk of adverse health effects [risk assessment]...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of allergy and clinical immunology

دوره 121 3  شماره 

صفحات  -

تاریخ انتشار 2008