harmonic limits using wide - spectrum passive harmonic filter

نویسنده

  • ANDY LAWSON
چکیده

T O ADDRESS CONCERNS ASSOCIATED WITH ELECTRICAL POWER system harmonic distortion on ships and offshore oil rigs and platforms, marine regulating bodies have introduced strict new harmonic standards. These standards define the acceptable level of harmonic voltage distortion allowed on the vessels they certify. High-harmonic distortion levels are appearing as a result of the increased use of power-electronic drive converters for electric propulsion, drilling and pumping applications, and many other uses of variable speed-drive (VSD) systems. To meet these new standards, methods to control harmonics must be adopted. This article will discuss some of these methods and present an application where a unique wide-spectrum passive harmonic filter was used to meet harmonic limits on a cable-laying ship that previously required the use of rented generators to allow operation of VSDs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A graph search algorithm: Optimal placement of passive harmonic filters in a power system

The harmonic in distribution systems becomes an important problem due to an increase in nonlinear loads. This paper presents a new approach based on a graph algorithm for optimum placement of passive harmonic filters in a multi-bus system, which suffers from harmonic current sources. The objective of this paper is to minimize the network loss, the cost of the filter and the total harmonic disto...

متن کامل

Harmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure

Thyristor rectifiers are widely used in electric railways in order to control the speed. As a consequence of their usage in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Regarding different p...

متن کامل

Design and Control of a Novel hybrid Active Power Filter based on Load Harmonic Currents Separation with the aim of DC-link voltage minimization in voltage source converter

This paper proposes a new hybrid active power filter, including voltage source converter (VSC) based active power filter and Thyristor Controllable LC Passive Filter (TCLC-HAPF) for eliminating harmonic load current components and compensating reactive power. This new structure which is based on the separation of high and low-frequency components of load current idea can reduce the drawbacks of...

متن کامل

Optimal Sitting, Sizing, and Operation of Batteries and Passive Filters to Mitigate Over-voltage and Harmonic Problems in Distribution Networks with High Photovoltaic Penetration

Photovoltaic systems (PVs), despite their many advantages, may have effects such as power quality issues (voltage and harmonics increase), short-circuits level increase, protection issues, and transient stability for network. Some of these effects are due to the high PV penetration, which encounters the network with the over-voltage and harmonics problems. In this paper, the location, size and ...

متن کامل

Harmonic Mitigation Using Inverter Based Hybrid Shunt Active Power Filter

With the rapid developments and use of non linear loads, the controlling over the harmonic current to get and maintain power quality is becoming more important. Active power filters has been used to compensate the harmonic pollution in our power system. This paper presents a efficient model to compensate the current harmonics using the inverter based Shunt Active Power Filter, Passive Power Fil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009