Mechanical and clinical rationale of prototype bone reduction forceps.

نویسندگان

  • Brendan A Kluszynski
  • Andre M Wineland
  • Mimi S Kokoska
چکیده

OBJECTIVE To describe the mechanical rationale and clinical application of prototype right-angle reduction forceps. METHODS A pair of prototype right-angle reduction forceps was designed and manufactured specifically to improve the consistency and ease of fracture reduction. It was used to reduce mandible fractures of the mandible body, parasymphysis, and symphysis in 4 patients. The fractures ranged from minimally displaced to comminuted and displaced fractures. RESULTS The pilot monocortical holes used for insertion of the right-angle reduction forceps into the mandible were easier to drill than the old method of drilling angled holes for standard reduction forceps. The older method required constant guesswork as to the correct angle of the hole relative to the tines of the curved reduction forceps. The right-angle reduction forceps required no guesswork because the pilot hole is drilled at a right angle to the surface of the outer bone cortex and at more than 1 cm laterally on each side of the fracture line. There were no episodes of outer cortical bone avulsion or any necessity for redrilling new pilot holes. These forceps provided sufficient force for excellent reduction of the fracture edges. The design also provided improved access for plating superior and inferior to its shaft while it was engaged. CONCLUSIONS Although curved bony reduction forceps are standard in most mandibular plating sets, they provide less predictable and efficient reduction of fractures than the right-angle reduction forceps. Prototype reduction forceps require little to no additional training to use properly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vibration and Noise Reduction Optimization Design of Mine Chute with Foam Aluminum Laminated Structure

The mining chute is an important equipment in the process of coal transportation and coal screening preparation. During the working process, the mining chute will generate a lot of vibration and noise because of constantly friction and impact of gangue and coal blocks. In order to reduce the vibration and noise during the operation of the chute, a new type of foam aluminum laminated structure i...

متن کامل

SCIENTIFIC REPORT Development of Microelectromechanical Systems (MEMS) forceps for intraocular surgery

Aim: To develop silicon microforceps for intraocular surgery using Microelectromechanical Systems (MEMS) technology, the application of microchip fabrication techniques for the production of controllable three dimensional devices on the micrometre scale. Methods: Prototype MEMS forceps were designed and manufactured for intraocular surgery. Scanning electron microscopy was used to evaluate devi...

متن کامل

Development of Microelectromechanical Systems (MEMS) forceps for intraocular surgery.

AIM To develop silicon microforceps for intraocular surgery using Microelectromechanical Systems (MEMS) technology, the application of microchip fabrication techniques for the production of controllable three dimensional devices on the micrometre scale. METHODS Prototype MEMS forceps were designed and manufactured for intraocular surgery. Scanning electron microscopy was used to evaluate devi...

متن کامل

رزیابی کارآمدی پیچ جااندازی لوله ای شکل (Tube Reduction Screw TRS) در جا اندازی شکستگی های مایل تنه ماندیبل : یک مطالعه آزمایشگاهی در ماندیبل لاشه گوسفند

Introduction & Objective: The highest rate of non-anatomic reduction of fractures is usually seen in oblique mandibular body fractures. Thus, the aim of the present study was the as-sessment of reduction performance of TRS (Tube Reduction Screw) in comparison conven-tional method (Reduction forceps with Lag Screws). Materials & Methods: This experimental study was conducted on 30 half- mandible...

متن کامل

A new obstetrical polyurethane versus stainless steel forceps: a comparison of forces generated to the base of the fetal skull during simulated deliveries.

BACKGROUND Decreasing the maximum force applied during traction to the base of the fetal skull using a less rigid polyurethane forceps is the basis of this study. Our hypothesis was that less force would be generated with polyurethane forceps than with steel forceps. OBJECTIVE To test a new soft polyurethane obstetrical forceps for maximal force generated to the base of the skull during simul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of facial plastic surgery

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 2007