Monitoring device acceptance in implantable cardioverter defibrillator patients using the Florida Patient Acceptance Survey.

نویسندگان

  • Henneke Versteeg
  • Annemieke Starrenburg
  • Johan Denollet
  • Job van der Palen
  • Samuel F Sears
  • Susanne S Pedersen
چکیده

BACKGROUND Patient device acceptance might be essential in identifying patients at risk for adverse patient-reported outcomes following implantation of an implantable cardioverter defibrillator (ICD). We examined the validity and reliability of the Florida Patient Acceptance Scale (FPAS) and identified correlates of device acceptance in a Dutch cohort of ICD patients. METHODS Patients with a first-time ICD (N = 272, mean age = 59.2 ± 11.9, 82% men) recruited from the Erasmus Medical Center, Rotterdam, or the Medisch Spectrum Twente, Enschede, The Netherlands completed the FPAS, the Type D Scale, and the Hospital Anxiety and Depression Scale. RESULTS Exploratory and confirmatory factor analyses indicated that eliminating three items from the FPAS, leaving 12 items contributing to three factors, is equivalent to the original four-factor version of the FPAS. The abbreviated FPAS had a high internal consistency both for the total scale and all subscales, with Cronbach's alphas ranging from 0.76 to 0.82. Anxiety (odds ratio [OR]: 9.75; 95% confidence interval [CI]: 2.38-39.87; P = 0.002), depression (OR: 2.96; 95% CI: 0.98-8.93; P = 0.05), and the distressed (Type D) personality (OR: 5.04; 95% CI: 1.50-16.92; P = 0.01), but not demographic and clinical factors including shocks, were significant independent correlates of poor device acceptance. CONCLUSION A shortened 12-item, three-factor version of the FPAS was shown to be a valid and internally consistent instrument to assess device acceptance in Dutch ICD patients. Psychological but not clinical factors were the primary correlates of device acceptance, which underlines the importance of taking into account the patient's psychological profile when seeking to identify patients at risk for adjustment difficulties after ICD implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

General and disease-specific psychosocial adjustment in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy with implantable cardioverter defibrillators: a large cohort study.

BACKGROUND Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is characterized by frequent life-threatening ventricular arrhythmias, diagnosed on average in the teens to mid-50s and commonly treated by implantable cardioverter defibrillators (ICDs). As younger age and high frequency of ICD discharges are risk factors for difficulties in psychosocial adjustment, we developed a st...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

No long-term psychological morbidity living with an implantable cardioverter defibrillator under advisory: the Medtronic Marquis experience.

AIMS It is unclear whether there is important psychological morbidity associated with living with an implantable cardioverter defibrillator (ICD) under advisory and whether this should be factored into decision-making. METHODS AND RESULTS Our study focused on patients living with advisory Medtronic Marquis ICDs. Patient adjustment to the ICD was evaluated using a validated device-specific met...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 2012