Time Duration of Oxygen Adaptation Immediately after Birth; Monitoring by Pulse Oximeter in Perinatal Period of the Infants at Charoenkrung Pracharak Hospital.
نویسندگان
چکیده
BACKGROUND Oxygen Saturation is one of the important data to determine patient status and worldwide applied in several situations. Evaluation about status of immediate perinatal period of the infant usually uses clinical assessment, Apgar scoring, which had been used for a long time without other scientific measurement. Pulse oximeter the non-invasive measurement of oxygen saturation, may play role for oxygen saturation evaluation in newborn that immediately change from intra to extra uterine environment. OBJECTIVE Monitoring the time duration that immediately born infants by normal labor or Cesarean section modes, used to archived target oxygen saturation (SpO) and looking for the other factors that influence oxygen saturation adaptation. MATERIAL AND METHOD The data of the 553 infants born in Charoenkrung Pracharak Hospital, Bangkok, Thailand between October 2012 and April 2013 were collected. The 204 healthy newborns that met all criteria were studied. All infants were recorded pulse oximeter from the second to the tenth minute after birth. They were grouped by several factors such as maternal gravidity, gestational age, mode of delivery, Apgar score, birth weight, and sex. Time interval to achieve target oxygen saturation (SpO2 ≥ 90%) was collected for analysis. RESULTS The oxygen saturation of infants immediately after birth showed an increase. Median time interval was 6.5 (2-10) minutes for 90% saturation and 7 (2-10) minutes for 95% saturation, respectively. Only mode of delivery showed statistical significant time difference (p < 0.001). A Cox proportional hazards analysis of the Kaplan-Meier curves demonstrated that infants born by cesarean delivery took significantly longer time to reach a stable SpO2 ≥ 90% than infants born by vaginal delivery (95% CI = 1.28 to 2.74; p < 0.01). CONCLUSION A newly born infant has to take 6.5 minutes (2-10) after birth to adjust their oxygen saturation to reach normal higher level of extra uterine life, median SpO2 of 90%. Furthermore, mode of delivery makes a significant difference of oxygen saturation status; the cesarean route takes significantly longer time than the vaginal route to achieve SpO2 ≥ 90%.
منابع مشابه
"New-generation" pulse oximeters in extremely low-birth-weight infants: how do they perform in clinical practice?
The aim of this study was to evaluate the performance of "new-generation" pulse oximeters in extremely low-birth-weight ([ELBW] ≤ 1000 g) infants. In a prospective crossover observational study, the performance of pulse oximeters of 3 brands (Masimo, Nellcor, and Philips) was evaluated by dual SpO2 measurement in ELBW infants. Disposable probes of either equal or different brands were placed ar...
متن کاملPerinatal Outcomes of Newborn Infants Conceived by Assisted Reproductive Techniques in Royan Institute
Background The outcomes of such pregnancies have been rarely evaluated in our country. A descriptive study was planned to assess the health and condition of neonates conceived with assisted techniques in a one year period. MaterialsAndMethods At Royan Institute, Tehran, 443 women who became pregnant by one of the assisted techniques in vitro fertilization (IVF), intrauterine insemination (IUI) ...
متن کاملMacrolide resistant Streptococcus pneumoniae in Charoenkrung Pracharak Hospital, Thailand.
Macrolide resistant Streptococcus pneumoniae has been increasing rapidly in Southeast Asia. A review from 2000 through 2011 at Charoenkrung Pracharak Hospital that evaluated drug resistance to erythromycin found S. pneumoniae from 158 of the 390 (40.5%) patients: 3.6% intermediate, 36.9% highly resistant. A significant correlation was found between macrolide resistant S. pneumoniae and penicill...
متن کاملValidation of pulse oximetry for monitoring of hypoxaemic episodes in the late postoperative period.
We monitored 12 patients undergoing major abdominal surgery using a pulse oximeter (Nellcor N-200) and a transcutaneous oxygen tension monitor (TINA, Radiometer A/S) on the second or third night after operation. Of the shortest hypoxaemic episodes measured with the pulse oximeter (< or = 30 s duration), 78% also occurred in the transcutaneous oxygen tension measurement. Episodes of longer durat...
متن کاملEffect of Nail Polish on Pulse Oximetry Findings in Healthy Volunteers: A Randomized Clinical Trail
Background and Objectives: Pulse oximetry is the most common technique for monitoring hemoglobin oxygen saturation (SpO2). Different colors and brands of nail polish may cause disturbance in the reading and interpretation of oxygen saturation. The aim of this study was to determine the effect of different colors of nail polish on oxygen saturation measured by pulse oximeter. Methods: Thirty he...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Medical Association of Thailand = Chotmaihet thangphaet
دوره 98 7 شماره
صفحات -
تاریخ انتشار 2015