Biomechanical Comparison of a First- and a Second-Generation All-Soft Suture Glenoid Anchor

نویسندگان

  • John Erickson
  • Frank Chiarappa
  • Jonathan Haskel
  • Justin Rice
  • Adam Hyatt
  • James Monica
  • Aman Dhawan
چکیده

BACKGROUND All-soft tissue suture anchors provide advantages of decreased removal of bone and decreased glenoid volume occupied compared with traditional tap or screw-in suture anchors. Previous published data have led to biomechanical concerns with the use of first-generation all-soft suture anchors. PURPOSE/HYPOTHESIS The purpose of this study was to evaluate the load to 2-mm displacement and ultimate load to failure of a second-generation all-soft suture anchor, compared with a first-generation anchor and a traditional PEEK (polyether ether ketone) anchor. The null hypothesis was that the newer second-generation anchor will demonstrate no difference in loads to 2-mm displacement after cycling compared with first-generation all-soft suture anchors. STUDY DESIGN Controlled laboratory study. METHODS Twenty human cadaveric glenoids were utilized to create 97 total suture anchor sites, and 1 of 3 anchors were randomized and placed into each site: (1) first-generation all-soft suture anchor (Juggerknot; Biomet), (2) second-generation all-soft suture anchor (Suturefix; Smith & Nephew), and (3) a control PEEK anchor (Bioraptor; Smith & Nephew). After initial cyclic loading, load to 2 mm of displacement and ultimate load to failure were measured for each anchor. RESULTS After cyclic loading, the load to 2-mm displacement was significantly less in first-generation anchors compared with controls (P < .01). However, the load to 2-mm displacement was significantly greater in second-generation anchors compared with controls (P < .01). There was no difference in ultimate load to failure between the first- and second-generation all-soft suture anchors (P > .05). CONCLUSION The newer generation all-soft suture anchors with a theoretically more rigid construct and deployment configuration demonstrate biomechanical characteristics (specifically, with load to 2-mm displacement after cyclic loading) that are improved over first-generation all-soft suture anchors and similar to a traditional solid tap-in anchor. The configuration of these newer generation all-soft suture anchors appears to mitigate the biomechanical concerns of decreased load to failure with first-generation all-soft tissue suture anchors. CLINICAL RELEVANCE The theoretical advantages of all-soft anchors may be particularly valuable in revision surgery or in cases where multiple anchors are being placed into a small anatomic area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The histologic and biomechanical response of two commercially available small glenoid anchors for use in labral repairs.

BACKGROUND This study examined histologic characteristics and biomechanical performance of 2 commercially available, small glenoid anchors. METHODS Adult research dogs (n = 6) were used for histologic analysis. Anchors were inserted into the lateral rim of the glenoid using the manufacturer's protocol. The dogs were humanely euthanatized 8 weeks after anchor implantation, and the glenoids wer...

متن کامل

Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor.

Bioabsorbable suture anchors are commonly used for arthroscopic repair of rotator cuff and labrum lesions. They provide soft-tissue attachment to bone. They have been introduced to avoid complications such as artefacts on MRI scans, commonly seen with metal anchors. However, bioabsorbable implants may lead to other problems such as local osteolysis, cyst formation, soft tissue inflammation and ...

متن کامل

The "bony Bankart bridge" procedure: a new arthroscopic technique for reduction and internal fixation of a bony Bankart lesion.

Arthroscopic treatment of bony Bankart lesions can be challenging. We present a new easy and reproducible technique for arthroscopic reduction and suture anchor fixation of bony Bankart fragments. A suture anchor is placed medially to the fracture on the glenoid neck, and its sutures are passed around the bony fragment through the soft tissue including the inferior glenohumeral ligament complex...

متن کامل

Cyclic loading biomechanical analysis of the pullout strengths of rotator cuff and glenoid anchors: 2013 update.

PURPOSE The purpose of this study was to evaluate the biomechanical and design characteristics of newer suture anchors under cyclic loading. METHODS Suture anchors were tested in fresh porcine cortical and cancellous bone by cyclic loading (10 to 100 N for 200 cycles) followed by destructive testing parallel to the insertion axis at 12.5 mm per second. End points included ultimate failure loa...

متن کامل

Pullout strength of knotless suture anchors.

PURPOSE Suture anchors are used consistently for repairs of soft tissues, especially around the glenohumeral joint. These anchors can be used either arthroscopically or in an open procedure to anatomically restore the labrum and capsular tissues to the glenoid after avulsion injuries (Bankart lesion). The purpose of this study was to analyze the pullout strength of a new knotless suture anchor ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017