Gradient-free microfluidic flow labeling using thin magnetic films and remotely detected MRI.
نویسندگان
چکیده
Nuclear Magnetic Resonance (NMR) and Magnetic Resonance Imaging (MRI) may be employed as noninvasive measurements yielding detailed information about the chemical and physical parameters that define microscale flows. Despite these advantages, magnetic resonance has been difficult to combine with microfluidics, largely due to its low sensitivity when detecting small sample volumes and the difficulty of efficiently addressing individual flow pathways for parallel measurements without utilizing large electric currents to create pulsed magnetic field gradients. Here, we demonstrate that remotely-detected MRI (RD-MRI) employing static magnetic field gradients produced by thin magnetic films can be used to encode flow and overcome some of these limitations. We show how flow path and history can be selected through the use of these thin film labels and through the application of synchronized, frequency-selective pulses. This obviates the need for large electric currents to produce pulsed magnetic field gradients and may allow for further application of NMR and MRI experiments on microscale devices.
منابع مشابه
Compressive sampling with prior information in remotely detected MRI of microfluidic devices.
The design and operation of microfluidic analytical devices depends critically on tools to probe microscale chemistry and flow dynamics. Magnetic resonance imaging (MRI) seems ideally suited to this task, but its sensitivity is compromised because the fluid-containing channels in "lab on a chip" devices occupy only a small fraction of the enclosing detector's volume; as a result, the few microf...
متن کاملCompressed sensing of remotely detected MRI velocimetry in microfluidics.
NMR and MRI can yield detailed chemical and dynamic information about flow at microscopic resolutions, but suffer from low signal to noise relative to alternative techniques for flow measurements. In porous media and microfluidic devices, this sensitivity problem is further exacerbated by magnetic susceptibility broadening and low coil filling factor. Fortunately, remote detection can mitigate ...
متن کاملZooming in on microscopic flow by remotely detected MRI.
Magnetic resonance imaging (MRI) can elucidate the interior structure of an optically opaque object in unparalleled detail but is ultimately limited by the need to enclose the object within a detection coil; acquiring the image with increasingly smaller pixels reduces the sensitivity, because each pixel occupies a proportionately smaller fraction of the detector's volume. We developed a techniq...
متن کاملSteering of aggregating magnetic microparticles using propulsion gradients coils in an MRI Scanner.
Upgraded gradient coils can effectively enhance the MRI steering of magnetic microparticles in a branching channel. Applications of this method include MRI targeting of magnetic embolization agents for oncologic therapy. A magnetic suspension of Fe(3)O(4) magnetic particles was injected inside a y-shaped microfluidic channel. Magnetic gradients of 0, 50, 100, 200, and 400 mT/m were applied to t...
متن کاملEffects of thermal diffusion and chemical reaction on MHD transient free convection flow past a porous vertical plate with radiation, temperature gradient dependent heat source in slip flow regime
An analytical investigation is conducted to study the unsteady free convection heat and mass transfer flow through a non-homogeneous porous medium with variable permeability bounded by an infinite porous vertical plate in slip flow regime while taking into account the thermal radiation, chemical reaction, the Soret number, and temperature gradient dependent heat source. The flow is considered u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance
دوره 249 شماره
صفحات -
تاریخ انتشار 2014