A sensitive and

نویسندگان

  • Dion R. Brocks
  • Tara J. Spencer
  • Anooshirvan Shayeganpour
چکیده

PURPOSE: To develop an alternate high performance liquid chromatographic method (HPLC) for the analysis of the positive inotropic agent, milrinone, in rat and human plasma. METHODS: To plasma samples (0.1 mL), containing milrinone and the commercially available internal standard, amrinone, were added 0.15 mL of water and 0.35 mL of acetonitrile. Tubes were briefly vortexmixed and centrifuged. The supernatant was transferred to clean tubes and 3 mL of methanol: diethyl ether (5:95) was added. The tubes were vortex mixed, centrifuged, and reconstituted with the mobile phase and injected into the HPLC. Separation was accomplished using a reverse phase chromatography using C18 analytical column, and detection was afforded by monitoring the eluent at an ultraviolet wavelength of 326 nm. RESULTS: Standard curves were highly linear over the range 10 to 10000 ng/mL (r2>0.99). Recovery ranged from 52-69% over a 40-fold range of plasma concentrations from 50 to 2000 ng/mL. Intraand inter-day coefficient of variation and mean error in were less than 20% at plasma concentrations ranging from 10 to 1000 ng/mL. The utility of the assay was demonstrated in a pharmacokinetic evaluation of milrinone in two rats given intravenous bolus doses. CONCLUSION: The developed assay was sensitive, specific and appropriate for monitoring milrinone in rat or human plasma samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Reliable Routing Algorithm for Delay Sensitive Data in Body Area Networks

Wireless body Area networks (WBANs) include a number of sensor nodes placed inside or on the human body to improve patient health and quality of life. Ensuring the transfer and receipt of data in sensitive data is a very important issue. Routing algorithms should support a variety of service quality such as reliability and delay in sending and receiving data. Loss of information or excessive da...

متن کامل

Comet assay as a sensitive technique in occupational health studies; A literature review

Background: Occupational health is a sensitive field in many countries where occupational exposure needs attention due to the lack of awareness. Several businesses, including leather, textile, iron, steel, and dyeing industries use a variety of mutagenic and genotoxic chemicals. Exposure to these chemicals may pose serious health risks, including genetic damage to workers. Comet assay is a tech...

متن کامل

A New Formulation for Cost-Sensitive Two Group Support Vector Machine with Multiple Error Rate

Support vector machine (SVM) is a popular classification technique which classifies data using a max-margin separator hyperplane. The normal vector and bias of the mentioned hyperplane is determined by solving a quadratic model implies that SVM training confronts by an optimization problem. Among of the extensions of SVM, cost-sensitive scheme refers to a model with multiple costs which conside...

متن کامل

Investigation of Swelling Behavior and Mechanical Properties of a pH-Sensitive Superporous Hydrogel Composite

   The objective of the present study is to develop and investigate the swelling behavior of pH-sensitive Superporous Hydrogel (SPH) and SPH composite (SPHC). A novel superporous hydrogel containing poly (methacrylic acid-co-acrylamide) was synthesized from methacrylic acid and acrylamide through the aqueous solution polymerization, using N,N-methylenebisacrylamide as a crosslinker and ammonium...

متن کامل

Biocompatibility research of a novel pH sensitive ion exchange resin microsphere

The main objective of this study was to investigate biocompatibility and provide in vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The genera...

متن کامل

Biocompatibility research of a novel pH sensitive ion exchange resin microsphere

The main objective of this study was to investigate biocompatibility and provide in vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The genera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002