Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study

نویسندگان

  • Moritz Kaup
  • Tatjana Gruber-Rouh
  • Jan E Scholtz
  • Moritz H Albrecht
  • Andreas Bucher
  • Claudia Frellesen
  • Thomas J Vogl
  • Martin Beeres
چکیده

BACKGROUND Computed tomography (CT) low-dose (LD) imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems. PURPOSE To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA). MATERIAL AND METHODS CTPA scans from 60 prospectively randomized patients (28 men, 32 women) were examined in this study on a 15-year-old 16-slice CT scanner system. Standard CT (SD) settings were 100 kV and 150 mAs, LD settings were 100 kV and 50 mAs. Attenuation of the pulmonary trunk, various anatomic landmarks, and image noise were quantitatively measured; contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR) were calculated. Three independent blinded radiologists subjectively rated each image series using a 5-point grading scale. RESULTS CT dose index (CTDI) in the LD series was 66.46% lower compared to the SD settings (2.49 ± 0.55 mGy versus 7.42 ± 1.17 mGy). Attenuation of the pulmonary trunk showed similar results for both series (SD 409.55 ± 91.04 HU; LD 380.43 HU ± 93.11 HU; P = 0.768). Subjective image analysis showed no significant differences between SD and LD settings regarding the suitability for detection of central and peripheral PE (central SD/LD, 4.88; intra-class correlation coefficients [ICC], 0.894/4.83; ICC, 0.745; peripheral SD/LD, 4.70; ICC, 0.943/4.57; ICC, 0.919; all P > 0.4). CONCLUSION The LD protocol, on a 15-year-old CT scanner system without current high-end hardware or post-processing tools, led to a dose reduction of approximately 67% with similar subjective image quality and delineation of central and peripheral pulmonary arteries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

Evaluation of the confounding factors disturbing the quality of CT images of pulmonary angiography

    Background: Since pulmonary angiography is the only non-invasive method for diagnosing pulmonary embolism, the use of radiation reduction methods without affecting the quality of images seems necessary. One of the simplest reasons for unnecessarily increasing of patient exposure is repetitive imaging due to poor image quality. Therefore, it is necessary to identify and ...

متن کامل

Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography.

UNLABELLED The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have high diagnostic accuracy. However, only limited data directly comparing these 2 modalities...

متن کامل

Evaluation of CT angiography findings in the patients with clinical diagnosis of pulmonary thromboembolism

Background and Aim: Pulmonary thromboembolism is an important clinical problem in the patients after major surgeries and is often difficult to diagnose because of nonspecific clinical symptoms. Diagnosis of pulmonary embolism is based on medical imaging methods. The aim of this study was to evaluate the results of CT pulmonary angiographies of the patients with primary clinical diagnosis of pul...

متن کامل

High-Pitch CT Pulmonary Angiography in Third Generation Dual-Source CT: Image Quality in an Unselected Patient Population

OBJECTIVES To investigate the feasibility of high-pitch CT pulmonary angiography (CTPA) in 3rd generation dual-source CT (DSCT) in unselected patients. METHODS Forty-seven patients with suspected pulmonary embolism underwent high-pitch CTPA on a 3rd generation dual-source CT scanner. CT dose index (CTDIvol) and dose length product (DLP) were obtained. Objective image quality was analyzed by c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016