Evaluation of OneTouch Verio(®), a new blood glucose self-monitoring system for patients with diabetes.
نویسندگان
چکیده
INTRODUCTION Self-monitoring of blood glucose (SMBG) is important in diabetes management. Reliable and user-friendly instruments are essential. OneTouch Verio(®) is a new blood glucose concentration-measuring system designed to be used by patients with diabetes and healthcare professionals. The objective of the present study was to evaluate the analytical performance of the OneTouch Verio(®). METHOD The OneTouch Verio(®) was evaluated by the Scandinavian evaluation of laboratory equipment for primary healthcare (SKUP) according to a protocol based on ISO 15197 and the American Diabetes Association (ADA) quality goals. Blood samples were collected and measured on the OneTouch Verio(®) by laboratory personnel and patients with diabetes (n = 91, randomized into groups receiving personal training or mail instructions for the OneTouch Verio(®) system). Results were compared to a validated routine method, imprecision and bias were calculated. User-friendliness was evaluated with a questionnaire. RESULTS Quality specifications for blood glucose concentration monitoring systems according to ISO 15197 were fulfilled. The mean coefficients of variation (CV%) of repeatability was 3.4% when tested by laboratory personnel and within the goal of imprecision suggested by ADA. Mean CV% of repeatability for patient self-monitoring was 5.0% and 5.1% in the training- and the mail group, respectively. Total error was 6.4-10.0%. The OneTouch Verio(®) showed no hematocrit interference or variation between strip lots. CONCLUSION The OneTouch Verio(®) displayed sufficient analytical quality and satisfactory user-friendliness. It is suitable for point-of-care testing of blood glucose concentration when handled by patients and healthcare professionals.
منابع مشابه
Analysis of an electrochemical blood glucose monitoring system with hematocrit compensation: improved accuracy by design.
The article entitled "Hematocrit Compensation in Electrochemical Blood Glucose Monitoring Systems" by Teodorczyk and colleagues in this issue of Journal of Diabetes Science and Technology demonstrates that the OneTouch(®) Verio™ glucose meter meets current regulatory expectations for glucose meter performance and is relatively free from interference by hematocrit. The lack of influence of hemat...
متن کاملAnalysis Article on the Performance Analysis of the OneTouch® UltraVueTM Blood Glucose Monitoring System
In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch® UltraVueTM blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether...
متن کاملAutomated glycemic pattern analysis: overcoming diabetes clinical inertia.
The OneTouch® Verio™ IQ Meter with PatternAlert™ Technology has been approved by the U.S. Food and Drug Administration as the first self-glucose monitor that can automatically determine glycemic patterns [high and low pre-meal blood glucose (BG)] for health care providers (HCPs) and patients. In this issue of Journal of Diabetes Science and Technology, Katz and coauthors demonstrate that this d...
متن کاملAnalysis article on the performance analysis of the OneTouch UltraVue blood glucose monitoring system.
In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch UltraVue blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 3...
متن کاملSystem accuracy of blood glucose monitoring devices according to the current and proposed ISO 15197 standards.
Corresponding Author: Guido Freckmann, M.D., Institut für Diabetes-Technologie Forschungsund Entwicklungsgesellschaft mbH, Helmholtzstrasse 20, 89081 Ulm, Germany; email address [email protected] In a letter to the editor, Teodorczyk and coauthors1 comment on our data2 published in Journal of Diabetes Science and Technology. In studies2 conducted at the Institut für Diabetes-Technologi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Scandinavian journal of clinical and laboratory investigation
دوره 73 4 شماره
صفحات -
تاریخ انتشار 2013