Lighting and discomfort in the classroom

نویسندگان

  • Mark Winterbottom
  • Arnold Wilkins
چکیده

Aspects of classroom lighting and décor that can promote discomfort and impair task performance through glare, and imperceptible 100 Hz flicker from fluorescent lighting, were examined in a sample of UK schools. In 90 classrooms, across eleven secondary schools and six local education authorities variables measured included flicker, illuminance at desks, and luminance of whiteboards. Results showed that 80% of classrooms are lit with 100 Hz fluorescent lighting that can cause headaches and impair visual performance. Mean illuminance (from excessive dayand artificial lighting) was in excess of recommended design illuminance in 88% of classrooms, and in 84% exceeded levels beyond which visual comfort decreases. Lighting could not be adequately controlled due to classroom design and infrastructure. Ceiling-mounted data-projectors directed at whiteboards mounted vertically on the wall resulted in specular reflection from the whiteboard, visible as a glare spot with luminance high enough to cause discomfort and disability glare. The intensity of the glare spot varied between different brands of whiteboard. Ambient lighting, needed for close work at pupils’ desks, reduced image contrast. Venetian blinds in 23% of classrooms had spatial characteristics appropriate for inducing pattern glare. There was significant variation between schools and local authorities. These findings may provide insights into small-scale reports linking pupils’ attainment, behaviour and learning to classroom lighting, and may also help explain some of the benefits of coloured overlays for pupils’ reading. 2008 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Classroom Lighting Control Systems and Level of Energy Consumption, Tehran, Iran

Buildings play an important role in the energy demand sector. Due to the increase of environmentalconcerns and renewable energy sources restriction, lighting control systems will play an important role in the reductionof energy consumption of the lighting without impeding comfort goals. Lighting control systems can control lightingconsumption according to the type of building, adequate luminanc...

متن کامل

ارزیابی روشنایی داخلی مدارس دخترانه شهر همدان در سال‌های 85 و 93

Introduction: In an educational environment, the quality of vision is integral to educational progress. Creating visual comfort and increasing efficiency and the desire to study are among the benefits of adjusting the lighting in classrooms and preventing visual impairment in the students. The present study was conducted to evaluate the degree of internal lighting in girls' schools across ...

متن کامل

Measuring The Quality Of Natural Lighting In A Building With Double Skin Façade (Dsf)

Lately, a double skin façade (DSF) has been increasingly popular as an aesthetic and shading device. A façade with a secondary skin is employed in buildings to let natural light flow into the building without glare and heat. The purpose of this study is to examine the performance of secondary skin in buildings and to investigate the level of natural lighting in buildings that meets visual comfo...

متن کامل

Evaluation of Combination of Natural and Artificial Lighting Condition in Primary Schools (Case Study: Baneh City of Kurdistan Province, Iran)

Background & Aims of the Study: Promoting the health and safety is an important part of the fundamental mission of schools and one factor in designing and operating schools that always has been important is lighting. As students spend considerable hours in the classroom and school, lighting should be designed appropriately and in accordance with the standards, to protect them...

متن کامل

ارزیابی ناراحتی بصری در کارمندان (کاربران رایانه) دانشگاه علوم پزشکی تهران

Background: People spend many times a day at work and they mostly do their work using computer. Today, computers are an integral part of the workplace, especially in office environments. The purpose of present study is to explore visual discomfort among office staff of Tehran university of Medical Sciences. Methods: This is a cross-sectional analytical study and was done in 2012. Sample size w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016