Technical Advances in Current PET and Hybrid Imaging Systems

نویسنده

  • Jae Sung Lee
چکیده

The continuing efforts of investigators to achieve the best physical and clinical performances from PET (positron emission tomography) and related hybrid cameras (PET/CT and PET/MRI) have led to remarkable technical advances in hardware and software. Time of flight (TOF) information measurement, which has been enabled thanks to the invention of fast, heavy crystals and advances in fast light detection sensors and readout electronics, is used to obtain the PET images of better quality and lesion-detection performance. Statistical reconstruction with resolution recovery and measurements of depth of interaction (DOI) are the useful softwareand hardware-wise approaches for enhancing the spatial resolution of reconstructed PET images. These technical advances along with an expansive increase in the number of PET and PET/CT examinations performed are facilitating the widespread use of PET scanners with specific detector structures and arrangements for particular applications or organs. Combined multimodal imaging systems are also in the development mainstream of these

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

Technical Challenges & Opportunities of PET/MR: An Overview

Following PET/CT, PET/MR is the newest diagnostic whole-body hybrid imaging modality. Simultaneous PET and MR data acquisition requires novel technical solutions and offers new diagnostic opportunities. Attenuation correction (AC) and motion correction (MC) of PET data are current hot topics in PET/MR hybrid imaging research. The added diagnostic value of PET/MR in whole-body imaging is current...

متن کامل

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

Recent advances in hybrid molecular imaging systems.

Nuclear medicine imaging methods that use radionuclides, such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT), offer highly sensitive and quantitative tools for the detection and localization of the biochemical and functional abnormalities associated with various diseases. The introduction of dual-modality PET/CT and SPECT/CT systems to the clinical ...

متن کامل

Uncertainties in effective dose estimation for CT transmission scan in total body PET-CT imaging with Auto mA3D tube current modulation

Background: Positron Emission Tomography-Computed Tomography (PET-CT) is a useful hybrid imaging modality in the diagnosis of various malignancies. This modality imposes almost 20 mSv radiation dose to the patient. The purpose of the present study was to evaluate the uncertainties in calculated CT effective dose in TUBE CURRENT MODULATION-activated scans by Impact-Dose software.  Materials and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010