CryoLife O'Brien aortic stentless prosthesis reoperations: clinical results and morphologic findings.
نویسندگان
چکیده
OBJECTIVES The CryoLife O'Brien (CLOB) stentless porcine aortic prosthesis has shown limited long-term durability, but its deterioration mechanisms have not yet been identified. The aim of this study was to review our experience with CLOB reoperations and to investigate the pathobiology of structural valve deterioration (SVD). METHODS Between March 1996 and December 2010, 35 patients underwent reoperation 82 ± 43 months after a CLOB implant. Patient records were retrospectively reviewed and follow-up was 100% complete. Nine valves explanted for SVD underwent pathological study. RESULTS Nineteen patients (54%) were operated on urgently for prosthetic valve replacement. No intraoperative technical complications occurred, and only one patient underwent aortic root replacement. One patient (3%) died in-hospital. Prosthesis dysfunction was due to SVD in 27 patients, caused by cusp commissural tearing in 22. All the nine explanted valves submitted to pathological examination showed calcifications and lipid insudation. At histology, eight prostheses disclosed cholesterol clefts and all showed a chronic inflammatory infiltrate. Transmission electron microscopy disclosed the presence of calcific deposits on cell debris and collagen fibres and confirmed the presence of cholesterol clefts. After a mean follow-up of 50 ± 33 months, survivals at 1, 5 and 7 years were 91 ± 5, 56 ± 9 and 38 ± 13%, respectively. CONCLUSIONS The CLOB reoperation is a feasible procedure, with satisfactory postoperative and mid-term survival results. Cusp tears, due to lipid and calcium deposits mostly targeting the commissures, seem to be the most important mechanism of SVD, resulting even in acute prosthetic incompetence and urgent reoperation.
منابع مشابه
Eight-year results after aortic valve replacement with the CryoLife-O'Brien Stentless Aortic Porcine Bioprosthesis.
OBJECTIVE The long-term durability and hemodynamics of stentless valves are largely unknown. In this study we prospectively analyzed 8-year clinical results with the CryoLife-O'Brien Stentless Aortic Porcine Bioprosthesis (CryoLife Inc, Kennesaw, Ga) and assessed its hemodynamic performance by serial echocardiography. METHODS A total of 206 patients with a mean age of 72.8 years were followed...
متن کامل[Aortic valve replacement with a Cryolife O'Brien stentless bioprosthesis].
INTRODUCTION AND OBJECTIVES The Cryolife O'Brien xenograft is a stentless bioprosthesis constructed from noncoronary leaflets from three porcine aortic valves. The aim of this study was to investigate short-term results after aortic valve replacement with this composite xenograft. METHODS Since October 1993, Cryolife O'Brien bioprostheses have been implanted in 210 patients. The patients' mea...
متن کاملUsefulness of the Cryolife O'Brien stentless suprannular aortic valve to prevent prosthesis-patient mismatch in the small aortic root.
OBJECTIVES This study evaluated the occurrence of prosthesis-patient mismatch (PPM) after Cryolife O'Brien (CLOB) suprannular stentless valve replacement in patients with a small aortic root and its repercussions on the patient's hemodynamic status and left ventricular mass regression. BACKGROUND The correct management of the small aortic annulus is still controversial. Small aortic prosthese...
متن کاملLimited long-term durability of the Cryolife O'Brien stentless porcine xenograft valve.
BACKGROUND Despite the fact that early and midterm hemodynamic and clinical results of the Cryolife O'Brien (CLOB) stentless valve have been reported to be favorable, the long-term durability and clinical results of this valve are largely unknown. Accordingly, we analyzed 10-year outcomes after aortic valve replacement with this valve. METHODS AND RESULTS From January 1994 to September 2004, ...
متن کاملHaemodynamics and left ventricular mass regression: a comparison of the stentless, stented and mechanical aortic valve replacement.
OBJECTIVE Our objective was to compare the degree of change in hemodynamics and left ventricular mass (LVM) regression after aortic valve replacement (AVR) with stentless, stented and mechanical valves. METHODS Patients greater than 59 years of age had AVR for aortic stenosis with the stentless xenograft (Cryolife-O'Brien, CLOB), stented xenograft (Carpentier-Edwards, C-E) or mechanical valve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 43 4 شماره
صفحات -
تاریخ انتشار 2013