Flow rate measurement in modern ambient air samplers – how accurate ?
نویسندگان
چکیده
New generation ambient air samplers operate at much lower sampling flow rates than do their “high volume” predecessors, namely 16.7 liters/minute. When these new air samplers emerged several years ago there were limited tools available with which to assess and calibrate their operating flow rate. In 1996 a flow meter specifically designed for these new air samplers came available, known as the StreamlineTM Flow Transfer Standard. With the establishment of a nation wide PM2.5 sampling network in 1999 which use exclusively 16.7 liter/minute samplers, Streamlines have come into wide usage. This paper addresses the “accuracy” of flow measurements produced by Streamline FTSs, and the subsequent accuracy of the flow rates of air samplers calibrated with Streamlines. A statistical uncertainty analysis was performed for the Streamline FTS used at a nominal flow rate of 16.5 liters/minute, yielding an uncertainty in its measured flow rate of ±0.67% which corresponds to ±0.11 liters/minute. A subsequent uncertainty analysis was performed for the flow rate of an ambient air sampler using a Streamline and a typical field instruments, yielding an uncertainty of ±0.98% (±0.16 liters/minute) at 16.7 liters/minute.
منابع مشابه
Uncertainty associated with the gravimetric measurement of particulate matter concentration in ambient air.
UNLABELLED This work applied a propagation of uncertainty method to typical total suspended particulate (TSP) sampling apparatus in order to estimate the overall measurement uncertainty. The objectives of this study were to estimate the uncertainty for three TSP samplers, develop an uncertainty budget, and determine the sensitivity of the total uncertainty to environmental parameters. The sampl...
متن کاملThe Use of Diffusive Samplers for Monitoring of Ambient Air
Diffusive monitors have been used for workplace air monitoring for many years, and in many cases have been found to be valid and cost-effective alternatives to conventional pumped or ‘active’ samplers. The state of the art of diffusive sampling is reviewed briefly, with particular reference to workplace air monitoring, and the potential for using similar or adapted devices for measuring concent...
متن کاملارزیابی مقایسه ای عملکرد نمونه بردارهای ذرات کل و قابل تنفس در سنجش تراکم میست کروم شش ظرفیتی
Background and Aim: Hexavalent chromium (Cr6+) is a known occupational carcinogen. Over the recent years, the increasing number of exposed workers and the emergence of serious health effects have led to considerable lowering of permissible exposure levels for Cr6+. Moreover, a number of methods have been developed for rapid and precise measurement of Cr6+concentrations. Given the importance of ...
متن کاملPerformance Characteristics of Personal Samplers in Still and Moving Air
Personal samplers or in general blunt body samplers are widely used in occupational hygiene for collecting air contaminants in the work environments. This work is part of an ongoing research into the performance evaluation of personal samplers, particularly in terms of their aerodynamic properties. Velocity profiles have been measured around and within typical cylindrical sampling devices, ...
متن کاملCollection Efficiencies of High Flow Rate Personal Respirable Samplers When Measuring Arizona Road Dust and Analysis of Quartz by X-ray Diffraction
Prolonged exposure to respirable crystalline silica (RCS) causes silicosis and is also considered a cause of cancer. To meet emerging needs for precise measurements of RCS, from shorter sampling periods (<4 h) and lower air concentrations, collaborative work was done to assess the differences between personal respirable samplers at higher flow rates. The performance of FSP10, GK2.69, and CIP 10...
متن کامل