Apparent viscoelastic anisotropy as measured from nondestructive oscillatory tests can reflect the presence of a flaw in cortical bone.

نویسندگان

  • Yener N Yeni
  • Gregory T Christopherson
  • A Simon Turner
  • Clifford M Les
  • David P Fyhrie
چکیده

There is evidence that damage, viscoelastic stiffness properties, and postyield mechanical properties are related in bone tissue. Our objective was to test whether presence of a flaw would have an influence on the apparent viscoelastic properties of bone. Examining the effect of flaw orientation on apparent viscoelastic properties and utilization of dynamic mechanical analysis (DMA) as a nondestructive means for detection of damage were our secondary objectives. Cortical bone beams (2 x 2 x 19 mm) machined from the cranial cortex of the radii of six Warhill sheep were used. The specimens were placed in a DMA machine and baseline measurements of storage modulus (E1) and loss factor (tan delta), once for loads in the craniocaudal and once in the mediolateral directions, were performed using a three-point bending configuration for a frequency range of 1-10 Hz. Craniocaudal/mediolateral measurement ratio was calculated as a measure of anisotropy for tan delta and E1. After cutting a thin through-thickness macroscopic notch on the caudal surface at the center of each beam, oscillatory tests were repeated. Two-way repeated measures analysis of variance followed by Tukey's test was used with group (craniocaudal, mediolateral, notched craniocaudal, and notched mediolateral measurements) and frequency as factors. Regression analysis and analysis of covariance were used for examining the relationship between viscoelastic parameters and frequency. Tan delta and E1 were not different between craniocaudal and mediolateral measurements before the flaw was introduced (p > 0.8 and p = 1, respectively). In the presence of the flaw, tan delta was significantly increased (p < 0.003) whereas E1 was significantly reduced (p < 0.001) for craniocaudal measurements. Tan delta and E1 were nearly isotropic in the tested directions before the introduction of a flaw into the bone tissue. Introduction of a flaw resulted in increased tan delta and E1 anisotropy. Presence of a notch resulted in a significant increase in tan delta anisotropy with increasing frequency. In conclusion, we have demonstrated that cortical bone tissue exhibits a different apparent viscoelastic behavior in the presence of a flaw and depending on the flaw's orientation. Our finding that the presence of a notch and its orientation can be detected by nondestructive DMA suggests that in vivo techniques may be developed for detection of cortical bone damage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of yield damage on the viscoelastic properties of cortical bone tissue as measured by dynamic mechanical analysis.

We have previously shown, using Dynamic Mechanical Analysis (DMA), that the presence of a defect in cortical bone tissue affects the apparent viscoelastic properties of that bone. However, mechanically induced damage is more complex than a machined defect making it difficult to predict its effect on bone viscoelasticity. We performed DMA measurements before and after introduction of yield damag...

متن کامل

Thermal Convection in a (Kuvshiniski-type) Viscoelastic Rotating Fluid in the Presence of Magnetic Field through Porous Medium (TECHNICAL NOTE)

  The effect of magnetic field on an incompressible (Kuvshiniski-Type) viscoelastic rotating fluid heated from below in porous medium is considered. For the case of stationary convection, magnetic field and medium permeability have both stabilizing and destabilizing effect on the thermal convection under some conditions whereas rotation has a stabilizing effect on the thermal convection. In the...

متن کامل

An Experimental Study on Evaluation of Factors Influencing the Viscosity and Viscoelastic Properties of Waxy Crude Oil

The influences of several operating factors on the viscosity of the Isfahan refinery waxy crude oil sample are studied through conducting some rheological shear rotational tests. The Taguchi design method is adopted to determine the impact of factors such as shear rate, temperature, cooling rate, wax content, and asphaltene content on the viscosity of the waxy crude oil. The results show that t...

متن کامل

Design of Nondestructive System for Hardness of Carbonitrided Steel Parts ‎Using Eddy Current Testing Method: Case study on the Tappet Parts

In this paper, a non-destructive eddy current test system was designed to evaluate the surface hardness of the carbonitrided steel parts. For this purpose, various samples of the tappet were used after the surface hardening and grinding operations as control samples and, if necessary, were subjected to destructive and non-destructive tests. Microstructural studies were performed with a microsco...

متن کامل

Effect of Polymer Grade and Plasticizer Molecular Weights on Viscoelastic Behavior of Coating Solutions

Film coating solutions containing different grades of HPMC (E5, E15 and E50) with and without polyethylene glycol (with various molecular weights) were examined by an oscillatory method, using Haake CV 100 rheometer. Fundamental rheological parameters (?, G? and G² ) were measured over the frequency range from 0.04 to 2 Hz. The variation with frequency of the loss tangent (a ratio of viscous to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part A

دوره 69 1  شماره 

صفحات  -

تاریخ انتشار 2004