Automated volumetric analysis of interface fluid in descemet stripping automated endothelial keratoplasty using intraoperative optical coherence tomography.
نویسندگان
چکیده
PURPOSE We demonstrated a novel automated algorithm for segmentation of intraoperative optical coherence tomography (iOCT) imaging of fluid interface gap in Descemet stripping automated endothelial keratoplasty (DSAEK) and evaluated the effect of intraoperative maneuvers to promote graft apposition on interface dimensions. METHODS A total of 30 eyes of 29 patients from the anterior segment arm of the PIONEER study was included in this analysis. The iOCT scans were entered into an automated algorithm that delineated the spatial extent of the fluid interface gap in three dimensions between donor and host cornea during surgery. The algorithm was validated against manual segmentation, and performance was evaluated by absolute accuracy and intraclass correlation coefficient. Patients underwent DSAEK using a standard sequence of maneuvers, including controlled elevation of IOP and compressive corneal sweep to promote graft adhesion. Measurement of interface fluid volume, en face area, and maximal interface height were compared between scans before anterior chamber infusion, after pressure elevation alone, and after corneal sweep with pressure elevation using dependent-samples t-test. RESULTS The algorithm achieved 87% absolute accuracy and an intraclass correlation of 0.96. Nine datasets of a total of 84 (11%) required human correction of segmentation errors. Mean interface fluid volume was significantly decreased by corneal sweep (P = 0.021) and by both maneuvers combined (P = 0.046). Mean en face area was significantly decreased by corneal sweep (P = 0.010) and the maneuvers combined (P < 0.001). Maximal interface height was significantly decreased by pressure elevation (P = 0.010), corneal sweep (P = 0.009), and the maneuvers combined (P = 0.010). CONCLUSIONS Quantitative analysis of iOCT volumetric scans shows the significant effect of controlled pressure elevation and corneal sweep on graft apposition in DSAEK. Computerized iOCT analysis yields objective measurements of interface fluid intraoperatively, which provides information on anatomic outcomes and could be used in future trials.
منابع مشابه
Intraoperative use of spectral-domain optical coherence tomography during Descemet’s stripping automated endothelial keratoplasty
PURPOSE To evaluate the intraoperative changes in the donor lenticule, recipient cornea, and the reduction of interface fluid thickness during Descemet's stripping and automated endothelial keratoplasty with EndoGlide™ (Angiotech Pharmaceuticals Inc, Vancouver, Canada) donor insertion, using intraoperative spectral-domain optical coherence tomography. METHODS Prospective observational case se...
متن کاملEfficacy of Intraoperative Anterior Segment Optical Coherence Tomography during Descemet's Stripping Automated Endothelial Keratoplasty
Purpose. To examine the graft-host interface during Descemet's stripping automated endothelial keratoplasty (DSAEK) surgery with optical coherence tomography (OCT). Design. Prospective, interventional case series. Patients and Methods. Eight patients who underwent a DSAEK were included. A handheld OCT was used intraoperatively to examine the presence of interface fluid between the host cornea a...
متن کاملDescemet stripping automated endothelial keratoplasty in Fuchs’ corneal endothelial dystrophy: anterior segment optical coherence tomography and in vivo confocal microscopy analysis
BACKGROUND To evaluate the in vivo corneal changes using in vivo confocal microscopy (IVCM) and anterior segment optical coherence tomography (AS-OCT) in patients with Fuchs' dystrophy who underwent Descemet stripping automated endothelial keratoplasty (DSAEK) and the relationship between these changes and the postoperative visual recovery up to 1-year follow-up. METHODS Before DSAEK and 1 da...
متن کاملGraft Suturing for Lenticule Dislocation after Descemet Stripping Automated Endothelial Keratoplasty
PURPOSE To report the mid-term outcomes of graft suturing in a patient with lenticule dislocation after Descemet stripping automated endothelial keratoplasty (DSAEK). CASE REPORT A 78-year old woman was found to have graft dislocation involving the nasal half of the cornea after uneventful DSAEK. Graft repositioning, refilling the anterior chamber with air, and placement of four full-thicknes...
متن کاملRepair of descemet membrane detachments with the assistance of anterior segment optical coherence tomography.
Extensive Descemet membrane detachment (DMD) is a rare complication of intraocular surgery that can lead to corneal decompensation. Although DMD may resolve spontaneously, surgical repair frequently is required. The diagnosis may be difficult because corneal edema can obscure visualization of the Descemet membrane (DM). Ultrasonographic biomicroscopy (UBM) has been the standard for imaging DMD ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 55 9 شماره
صفحات -
تاریخ انتشار 2014