INTRODUCTION Radio-frequency catheter ablation (RFCA) using Joule heat has two fundamental weaknesses: the limited depth of treatment and the risk of thrombus formation. In contrast, focused shock wave (SW) therapy could damage tissues at arbitrary depths without heat generation. Thus, we aimed to develop a SW catheter ablation (SWCA) system that could compensate for the weaknesses of RFCA therapy. METHODS AND RESULTS We developed a SWCA system where the SW generated by a Q-switched Holmium: yttrium aluminum garnet (YAG) laser beam was reflected by a reflector attached to 14-Fr catheter tip and then was converged onto the focus. We examined the feasibility of our system on pigs in vivo. When applied using the epicardial approach, the SWCA caused persistent spheroidal lesions with mild superficial injury than the RFCA. The lesions were created to a depth based on the focal length (2.0 mm) [2.36 ± 0.45 (SD) mm immediately after procedure, n = 16]. When applied to the atrioventricular (AV) node using the endocardial approach, the SWCA caused junctional escape rhythms in 2 pigs and AV block in 12 pigs (complete AV block in 9) in acute phase (n = 14). Nine of the 14 pigs survived with pacemakers for the long-term study, and the AV block persisted for 12.6 ± 3.9 (SD) days in all surviving pigs. Histological examination showed AV nodal cell body atrophy in the acute phase and fibrotic lesions in the chronic phase. Importantly, no acute or chronic fatal complications were noted. CONCLUSIONS Our novel SWCA system could be a promising modality as a non-thermal ablation method to compensate for the weaknesses of RFCA therapy. However, further research and development will be necessary as the current prototype still exhibited the presence of micro-thrombus formation in the animal studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia

  Background: Catheter ablation is widely used for treatment of atrial fibrillation. The use of fluoroscopic and non-fluoroscopic mapping systems in catheter ablation is common. This study conducted to investigate the safety and effectiveness of Navx non-fluoroscopic mapping system.   Methods : In this study, the appropriate electronic databases including Cochrane Library and Ovid Medline searc...

متن کامل

Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation.

BACKGROUND Ablation of complex arrhythmias would be greatly facilitated by more precise control of ablation catheters. A feasibility study was performed in animals to evaluate a novel magnetic guidance system (MGS) that generates a magnetic field to control the movement and position of a magnetic ablation catheter. METHODS AND RESULTS The MGS is composed of a digital biplanar fluoroscope with...

متن کامل

Radiofrequency catheter ablation in the treatment of Wolff-Parkinson-White syndrome

Introduction: Tachyarrhythmias in Wolf Parkinson White (WPW) syndrome, can be a life threatening factor. Antiarrhythmic drug therapy in this syndrome, has not been completely acceptable. Efficacy, safety and economy of Radio Frequency Catheter Ablation (RFCA) in western studies, has made it as the treatment of choice. In the present study, efficacy of RFCA in the ablation of accessory pathway...

متن کامل

An Optical Measurement System to Measure Velocity and Provide Shock Wave Pressure Diagrams

This paper introduces an optical measurement system for shock wave characteristics. The system works by mountinga metal plate attached to spring mounts against the shock wavefront. This set is sealed and can plot the shock wave pressure diagram by measuring plate's displacement, radiation and changing the reflection of light during shock wave conflict, and converting these optical data to volta...

متن کامل

Pulmonary Embolism as a Complication after radiofrequency catheter ablation Study: A Case Report

Pulmonary thromboembolism (PTE) is a fatal condition that may rarely occur due to complications of coronary catheter insertion. In this case report, a 41-year-old male was presented 48 hours after radiofrequency catheter ablation(RFCA) for the management of Wolf-Parkinson-White syndromewith acute onset of dyspnea, hemoptysis, and chest pain. The physical examination revealed coarse crackles in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015