Scleral buckling with a noncontact wide-angle viewing system in the management of retinal detachment with undetected retinal break: a case report
نویسندگان
چکیده
A young patient who showed rhegmatogenous retinal detachment with preoperatively undetected retinal break was successfully treated by scleral buckling using a noncontact wide-angle viewing system.
منابع مشابه
Scleral buckling for primary rhegmatogenous retinal detachment using noncontact wide-angle viewing system with a cannula-based 25 G chandelier endoilluminator
PURPOSE To assess the outcome of scleral buckling surgery using a noncontact wide-angle viewing system for fundus visualization in patients with rhegmatogenous retinal detachment. METHODS Twenty-eight eyes of 28 patients underwent a modified scleral buckling surgery using a noncontact wide-angle viewing system combined with a 27-gauge optic fiber inserted into the sclera at the pars plana thr...
متن کاملScleral buckling procedure with chandelier illumination for pediatric rhegmatogenous retinal detachment
PURPOSE To assess the treatment of pediatric patients with rhegmatogenous retinal detachment (RRD) by scleral buckling with chandelier illumination. METHODS Three eyes were treated in three patients, healthy boys aged 7 years, 12 years, and 11 years, with RRD, macular involvement, and small retinal holes, of which two were preoperatively undetectable. Conventional scleral buckling with cryore...
متن کاملWide-Angle Viewing System versus Conventional Indirect Ophthalmoscopy for Scleral Buckling
Wide-angle viewing systems (WAVSs) were originally established for pars plana vitrectomy. However, their application to scleral buckling surgery was recently reported. In this study, we compared the outcomes of scleral buckling using a noncontact WAVS with that of scleral buckling using conventional indirect ophthalmoscopy for rhegmatogenous retinal detachment. The clinical records of 39 eyes (...
متن کاملScleral Buckling Using a Non-contact Wide-Angle Viewing System with a 25-Gauge Chandelier Endoilluminator
PURPOSE To report the outcome of scleral buckling using a non-contact wide-angle viewing system with a 25-gauge chandelier endoilluminator. METHODS Retrospective analyses of medical records were performed for 17 eyes of 16 patients with primary rhegmatogenous retinal detachment (RRD) without proliferative vitreoretinopathy who had undergone conventional scleral buckling with cryoretinopexy us...
متن کاملAcute bacterial endophthalmitis after scleral buckling surgery with chandelier endoillumination
Purpose The non-contact wide-angle viewing system (WAVS) with chandelier endoillumination is being used more commonly during scleral buckling surgery for rhegmatogenous retinal detachments although its safety has not been established. We report our findings in a case of bacterial endophthalmitis that developed after scleral buckling surgery with WAVS and chandelier endoillumination. Observati...
متن کامل