Trace analysis of benzalkonium chloride on skin by flow injection ionspray mass spectrometry-mass spectrometry.

نویسندگان

  • S Kawakami
  • R H Callicott
  • N Zhang
چکیده

A method for the analysis of trace-level benzalkonium chloride has been established using flow injection ionspray mass spectrometry-mass spectrometry with multiple reaction monitoring. Quantification was carried out using an external standard based on peak area summation of each benzalkonium ion (C8, C10, C12, C14, C16 and C18) in the mass spectra. The multiple reaction monitoring technique provides additional specificity for identification and quantification. The quantification linear dynamic range was found to be 5.0-100.0 ng ml-1, the correlation coefficient > 0.999, and the detection limit 1.2 ng ml-1. The method was applied to quantify benzalkonium chloride on skin, which was sampled with a D-SQUAME tape from skin surface and extracted from the tape with methanol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a method for rapid quantitation of amino acids by liquid chromatography-tandem mass spectrometry (LC-MSMS) in plasma.

A new analytical method has been developed and is proposed for the rapid determination of eighteen common amino acids, including tryptophan, in plasma and dried blood spots, by liquid chromatography coupled with ionspray tandem mass spectrometry. Potentially the method can include other amino acids and can be used for the diagnosis of metabolic disease. The use of the ionspray tandem mass spect...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

First identification of prednisone in human hair by liquid chromatography-ionspray mass spectrometry.

A wide range of methodologies have been investigated for the determination of corticosteroids in biological fluids, including radioimmunoassay (1), high-performance liquid chromatography (HPLC) with spectrophotometric detection (2), gas chromatography (3), and liquid or gas chromatography coupled to mass spectrometry (4,5). Blood or urine is usually employed to check drug consumption; however, ...

متن کامل

Trace analyses of arsenic in drinking water by inductively coupled plasma mass spectrometry: high resolution versus hydride generation.

A magnetic sector inductively coupled plasma mass spectrometer (ICPMS) was applied to the determination of arsenic in drinking water samples using standard liquid sample introduction in the high-resolution mode (M/delta M = 7800) and hydride generation in the low-resolution mode (M/delta M = 300). Although high mass resolution ICPMS allowed the spectral separation of the argon chloride interfer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 123 3  شماره 

صفحات  -

تاریخ انتشار 1998