A new optical transducer for arterial pressure measurement.

نویسندگان

  • C H Hackman
  • P S Tan
  • M K Chakrabarti
  • J G Whitwam
چکیده

A new optical pressure transducer system (Viggo) has been assessed and compared with a standard P10 transducer (Spectramed) using a similar 20-gauge cannula, both in vitro in terms of linearity and frequency response and in vivo using an animal model. The linearity of the transducers was comparable; the resonant frequencies were 106 Hz and 75 Hz, respectively. However, the resonant frequency of the complete Spectramed system including 150-cm tubing was 11 Hz. The frequencies at which the output amplitude error exceeded 10% of the initial amplitude for the Viggo and for P10 with and without 150-cm tubing were 32 Hz, 24 Hz and 4 Hz, respectively. The principal advantage of the new transducer is that it is sufficiently compact to be mounted directly in the cannula at the wrist, so obviating the use of connecting tubing between the transducer and the cannula.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر

Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...

متن کامل

Weight Measurements by Using Simple Optical-Fiber Sensors (RESEARCH NOTE)

The use of different optical-fiber sensors for weighing measurements is Abstract described. By using three different mechanical stressing mechanisms, the operation of the fiber-to-fiber transducer systems are tested and the results are presented. Parameters such as sensitivity, hysteresis, resolution, and dynamic range are measured. A comparison of the results has shown that the sensor system m...

متن کامل

Continuous ambulatory pulmonary artery pressure monitoring. A new method using a transducer tipped catheter and a simple recording system.

A transducer tipped catheter and simple recording system were used for the continuous measurement of ambulatory pulmonary artery pressure. The pulmonary artery pressure was recorded on a miniaturised tape recorder and replayed via an optical writer. Pulmonary arterial systolic and diastolic pressures can be analysed on a beat to beat basis. Continuous ambulatory monitoring was performed for a t...

متن کامل

An Optical Measurement System to Measure Velocity and Provide Shock Wave Pressure Diagrams

This paper introduces an optical measurement system for shock wave characteristics. The system works by mountinga metal plate attached to spring mounts against the shock wavefront. This set is sealed and can plot the shock wave pressure diagram by measuring plate's displacement, radiation and changing the reflection of light during shock wave conflict, and converting these optical data to volta...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 67 3  شماره 

صفحات  -

تاریخ انتشار 1991