On-line Wavelength Calibration of Pulsed Laser for Co2 Differential Absorption Lidar
نویسندگان
چکیده
Differential absorption lidar (DIAL) remote sensing is a promising technology for atmospheric CO2 detection. However, stringent wavelength accuracy and stability are required in DIAL system. Accurate on-line wavelength calibration is a crucial procedure for retrieving atmospheric CO2 concentration using the DIAL, particularly when pulsed lasers are adopted in the system. Large fluctuations in the intensities of a pulsed laser pose a great challenge for accurate on-line wavelength calibration. In this paper, a wavelength calibration strategy based on multiwavelength scanning (MWS) was proposed for accurate on-line wavelength calibration of a pulsed laser for CO2 detection. The MWS conducted segmented sampling across the CO2 absorption line with appropriate number of points and range of widths by using a tunable laser. Complete absorption line of CO2 can be obtained through a curve fitting. Then, the on-line wavelength can be easily found at the peak of the absorption line. Furthermore, another algorithm called the energy matching was introduced in the MWS to eliminate the backlash error of tunable lasers during the process of on-line wavelength calibration. Finally, a series of tests was conducted to elevate the calibration precision of MWS. Analysis of tests demonstrated that the MWS proposed in this paper could calibrate the on-line wavelength of pulsed laser accurately and steadily. * Corresponding author
منابع مشابه
Transmitter design for differential absorption water vapor LIDAR
We present a stabilized master-laser power-amplifier system for ground-based differential absorption LIDAR (DIAL) for profiling atmospheric water vapor. This system consists of two CW master lasers with the wavelength of each master laser actively stabilized. The system employs GaAlAs laser diodes for both the master lasers and the tapered laser amplifier. The on-line master laser is currently ...
متن کاملLaser Energy Monitor for Double-Pulsed 2-μm IPDA Lidar Application
Integrated path differential absorption (IPDA) lidar is a remote sensing technique for monitoring different atmospheric species. The technique relies on wavelength differentiation between strong and weak absorbing features normalized to the transmitted energy. 2-μm double-pulsed IPDA lidar is best suited for atmospheric carbon dioxide measurements. In such case, the transmitter produces two suc...
متن کاملLaser Amplifier Development for IPDA Lidar measurements of CO2 from Space
Accurate global measurements of tropospheric CO2 mixing ratios are needed to better understand the global carbon cycle and the CO2 exchange between land, oceans and atmosphere. NASA Goddard Space Flight Center (GSFC) is developing a pulsed lidar approach for an integrated path differential absorption (IPDA) lidar as a candidate for the NASA’s planned ASCENDS mission to allow global measurements...
متن کاملA Lidar Approach to Measure CO2 Concentrations from Space for the ASCENDS Mission
We report on a lidar approach to measure atmospheric CO2 column concentration being developed as a candidate for NASA’s ASCENDS mission. It uses a pulsed dual-wavelength lidar measurement based on the integrated path differential absorption (IPDA) technique. We demonstrated the approach using the CO2 measurement from aircraft in July and August 2009 over various locations. The results show clea...
متن کاملStabilized master laser system for differential absorption lidar.
Wavelength accuracy and stability are key requirements for differential absorption lidar (DIAL). We present a control and timing design for the dual-stabilized cw master lasers in a pulsed master-oscillator power-amplifier configuration, which forms a robust low-cost water-vapor DIAL transmitter system. This design operates at 823 nm for water-vapor spectroscopy using Fabry-Perot-type laser dio...
متن کامل