Evaluation of the Roche CoaguChek XS handheld coagulation analyzer in a cardiac outpatient clinic.
نویسندگان
چکیده
This study evaluated the performance of a handheld coagulation analyzer for measurements of capillary blood specimens of 93 outpatient cardiology patients with atrial fibrillation who were receiving oral anti-coagulant therapy. The international normalized ratio (INR) results of the CoaguChek XS system (Roche Diagnostics) were compared with those obtained in the central laboratory with citrated venous blood specimens using the ACL9000 coagulation analyzer (Instrumentation Laboratory). The INR results for prothrombin time by the CoaguChek XS analyzer were closely correlated with the central laboratory's results in the INR range of 0.96 approximately 8.53 (r = 0.964). A statistically significant difference was noted between 2 lots of test strips, but the difference was miniscule (mean +/- 95% confidence interval: 0.04+/-0.02). The CV of 8 replicate assays with the CoaguChek XS for a blood specimen with high INR value (INR=3.9) was 1.4%; for a blood specimen with medium INR value (INR=1.3), the CV of 8 replicate assays was <0.1%. This study shows that the CoaguChek XS analyzer is precise and reliable for assessment of INR results at clinically significant ranges in cardiac outpatients.
منابع مشابه
Data documenting the performance of the PT/INR line correction method for reconciling INR discrepancies between central laboratory coagulation analyzers using different thromboplastins during the evaluation of a portable Coagulometer
The data presented here was produced as part of an evaluation of the performance of the CoaguChek XS point-of-care coagulation analyzer, which is discussed in the research article "POCT PT INR - Is it adequate for Patient Care? A Comparison of the Roche Coaguchek XS vs. Stago Star vs. Siemens BCS in Patients Routinely Seen in an Anticoagulation Clinic" (Baker et al., in press) [1]. An effort to...
متن کاملSelf-monitoring of oral anticoagulation therapy in children.
This study aimed to investigate the accuracy of home International Normalized Ratio (INR) self-monitoring in pediatric patients on long-term oral anticoagulation therapy. Statistical and clinical agreement of INR values from capillary whole blood samples measured by 2 different portable prothrombin time monitors (CoaguChek S and XS) and venous blood samples measured by a laboratory coagulation ...
متن کاملAccuracy of capillary whole blood international normalized ratio on the CoaguChek S, CoaguChek XS, and i-STAT 1 point-of-care analyzers.
We evaluated the accuracy of capillary whole blood international normalized ratio (INR) on the CoaguChek S (Roche Diagnostics, Indianapolis, IN), CoaguChek XS (Roche Diagnostics), and i-STAT 1 (i-STAT, East Windsor, NJ) point-of-care (POC) analyzers compared with venous plasma INRs determined by a reference laboratory method. Overall agreement between POC and laboratory plasma INR was very good...
متن کاملComparison of International Normalized Ratio Measurement between CoaguChek XS Plus and STA-R Coagulation Analyzers
BACKGROUND Point-of-care testing (POCT) coagulometers are increasingly being used in the hospital setting. We investigated whether the prothrombin time international normalized ratio (INR) results by CoaguChek XS Plus (Roche Diagnostics GmbH, Mannheim, Germany) can be used reliably without being confirmed with the INR results by STA-R system (Diagnostica Stago S.A.S, Asnières sur Seine, France)...
متن کاملAccuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin.
Point-of-care INR (POC INR) meters can provide a safe and effective method for monitoring oral vitamin K antagonists (VKAs) in children. Stollery Children's Hospital has a large POC INR meter loan program for children requiring oral VKAs. Our protocol requires that POC INR results be compared to the standard laboratory INR for each child on several consecutive tests to ensure accuracy of CoaguC...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of clinical and laboratory science
دوره 38 1 شماره
صفحات -
تاریخ انتشار 2008