Adaptive Volumetric MR-guided High-Intensity Focused Ultrasound Ablations
نویسندگان
چکیده
Introduction Recent technological advances in the field of clinical high intensity focused ultrasound (HIFU) transducer systems and real time MR thermometry using PRF thermometry [1] lead to an increasing trend towards real time feedback control for the MR-guidance of thermal therapies with HIFU. In particular phased array HIFU systems with short beam repositioning times and large aperture/focal length ratios can benefit from this approach, since they allow to ablate larger tumor volumes in each ablation cycle. However, real time feedback control of the HIFU beam position and the beam power requires continuously updated volumetric information of the thermal dose [2] and temperature over the entire target area. Furthermore, usage on abdominal targets requires the possibility to extract target location in real time from the MRI data to allow the compensation of physiological motion [3]. Here, we present a dynamic volume sweep for volumetric and motion compensated MRthermometry and dosimetry in combination with a real time adaptation of the ablation trajectory for this purpose. The feedback control algorithm is based on the target temperature, as it is required for the use of HIFU in local drug delivery applications, or directly on thermal dose estimates as is preferable for the direct thermal destruction of tumors. Materials and Methods Volume sweep: Two slices are acquired for each dynamic scan (Figure 1a). One remains static and is placed in the center of the target area. The purpose of this slice is twofold: It provides thermometric information and updates of the current target location with a high temporal resolution. The second slice is dynamically repositioned for each dynamic scan to perform a volumetric sweep. This allows to sample the entire extend of the target volume, albeit at a lower temporal resolution. All slices are corrected for 2D motion and motion induced phase variations [4] Volume Control: The algorithm similar to [5] was implemented to allow volumetric control of the HIFU heating based on either temperature or thermal dose maps. This was achieved by continuously calculating the required acoustic energy for each voxel in the target area and adjusting the sonication trajectory following the local maxima. In order to meet the specific requirements of each control method and their applications, an additional spatial weighting was introduced. As a result, for temperature control (i.e. creating and maintaining an isothermal volume), inverse radial weighting was implemented in order to homogeneously heat a pre-defined target area. For thermal ablations using thermal dose control, radial weighting was used to reduce energy deposition outside the target area. The ablation trajectory (5 points of 25ms duration each) was dynamically recalculated after the arrival of every new dynamic scan (i.e. 8Hz update rate). Experimental setup: MR-imaging was performed on a 1.5 T Philips Achieva MR scanner (Philips Healthcare, The Netherlands) using the circular coil integrated in the Philips Sonalleve breast MR-HIFU platform. A single-shot EPI sequence (TR/TE = 125/30 ms, bandwidth = 1560 Hz, matrix 128x54x2, voxel = 2.5x2.5x3mm3, flip angle = 25°) was used for image acquisition for sustained imaging over a duration of 9min. The slice position was shifted by 3 mm for each dynamic acquisition covering a total volume of 2.1 cm along z. Heating was performed for 500s on a breast phantom with a maximal electric power of 60 W. The control algorithm was programed to either achieve a thermal dose of TDT=24 EM, or a temperature elevation of ΔT=6°C in a spherical target area of 2 cm diameter. Results and Discussion The results of the heating experiments are shown in Figure 2. The feedback control based on temperature achieved an isothermal area in the designated target after 80s. All target voxels showed at this point temperatures equal or higher than 6°C with maximal overshoots of 1.6°C. The control algorithm maintained a stable temperature (±0.1°C) over 7 min. Outside the target area, 74 voxels were heated above 6°C. Control based on the thermal dose delivered the pre-defined thermal dose to all targeted voxels after 80s. Energy deposition outside the target area was unavoidable as a result of the focal point shape and lead to thermal doses higher than the target value in 172 adjacent voxels. Conclusions The proposed strategy allows precise volumetric heating in the designated target area while remaining compatible with previously suggested motion compensation schemes. The approach accommodates feedback control based on both the temperature or the thermal dose depending on the particular application scenario. Hence, the described method is an interesting candidate for effective tumor ablations inflicting minimal damage on the healthy surrounding tissue.
منابع مشابه
Optimization of volumetric MR-guided high-intensity focused ulatrsound ablations in moving organs
Introduction In this work, a method for the optimization of volumetric MR-guided high intensity focused ultrasound (HIFU) ablations is presented. While commonly MRguidance of thermal therapies is based on temperature control the on-line assessment of the thermal dose has been suggested to determine the therapy endpoint [1]. Therefore, we propose to monitor the thermal dose [2] of the treated ti...
متن کاملSonalleve MR-HIFU with DISC Philips MR-guided High Intensity Focused Ultrasound with Direct Skin Cooling
High Intensity Focused Ultrasound guided by Magnetic Resonance Imaging (also known as MR-guided HIFU, MRgHIFU, or MRgFUS) is a therapy technique which uses focused ultrasound waves to heat and coagulate tissue deep inside the body without damaging intervening tissue and offers an novel, non-invasive treatment option for solid tumors. The Philips Sonalleve MR-HIFU system, initially released in 2...
متن کاملRobust binary feedback control of MR guided volumetric HIFU ablation
Volumetric High Intensity Focused Ultrasound (HIFU) ablation has several advantages as compared to the traditional point-by-point ablation, such as improved energy efficiency and homogeneous thermal lesions with sharp borders [1]. However, there is an increased risk of excessive off-focus heating, especially in the near-field [2], and the thermal lesions can also vary in shape and size due to l...
متن کاملVolumetric MR-guided high-intensity focused ultrasound ablation to treat uterine fibroids through the abdominal scars using scar patch: a case report
BACKGROUND Abdominal scars pose a challenge in magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) therapies, limiting patient selection and increasing the risk of skin burns. Especially, scars arising from longitudinal incisions are problematic as they usually lie medially at the lower abdomen where the ultrasound beam has to go through. Volumetric sonication has been shown t...
متن کاملHigh-intensity focused ultrasound for noninvasive functional neurosurgery.
Transcranial magnetic resonance (MR)-guided high-intensity focused ultrasound (tcMRgHIFU) implies a novel, noninvasive treatment strategy for various brain diseases. Nine patients with chronic neuropathic pain were treated with selective medial thalamotomies. Precisely located thermal ablations of 4mm in diameter were produced at peak temperatures of 51 degrees C to 60 degrees C under continuou...
متن کاملEffects of magnetic resonance-guided high-intensity focused ultrasound ablation on bone mechanical properties and modeling
BACKGROUND Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a promising technique for palliative treatment of bone pain. In this study, the effects of MR-HIFU ablation on bone mechanics and modeling were investigated. METHODS A total of 12 healthy rat femurs were ablated using 10 W for 46 ± 4 s per sonication with 4 sonications for each femur. At 7 days after treatment...
متن کامل