Imaging of acute subarachnoid hemorrhage with a fluid-attenuated inversion recovery sequence in an animal model: comparison with non-contrast-enhanced CT.

نویسندگان

  • R J Woodcock
  • J Short
  • H M Do
  • M E Jensen
  • D F Kallmes
چکیده

BACKGROUND AND PURPOSE Fluid-attenuated inversion recovery (FLAIR) MR imaging sequences have been previously described in the evaluation of acute subarachnoid hemorrhage (SAH) in human subjects and have demonstrated good sensitivity. The purpose of this study was to evaluate a FLAIR sequence in an animal model of SAH and to compare the results with those obtained with non-contrast-enhanced CT. METHODS SAH was experimentally induced in 18 New Zealand rabbits by injecting autologous arterial blood into the subarachnoid space of the foramen magnum. Nine animals had high-volume (1-2 mL) injections, and nine animals had low-volume (0.2-0.5 mL) injections. Four control animals were injected with 0.5 mL of saline. The animals were imaged with a FLAIR sequence and standard CT 2-5 hours after injection. Gross pathologic evaluation of seven of the animals was performed. Four blinded readers independently evaluated the CT and FLAIR images for SAH and graded the probability of SAH on a scale of 1 to 5 (1 = no hemorrhage, 5 = definite hemorrhage). RESULTS Overall, the sensitivity of FLAIR was 89%, and the sensitivity of CT was 39% (P <.01). In animals with a high volume of SAH, the sensitivity of FLAIR was 100%, and the sensitivity of CT was 56%. In animals with a low volume of SAH, the sensitivity of FLAIR was 78%, and the sensitivity of CT was 22%. The specificity of FLAIR in animals without SAH was 100%, and the specificity of CT was 100%. The average reader score for FLAIR was 3.8, and that for CT was 2.2 (P <.001). Reader scores for FLAIR were higher than those for CT in 94% (P <.01) of animals with SAH and in 25% of animals without SAH (P >.05). Seven animals underwent gross pathologic examination, and all had blood in the subarachnoid space around the brain stem. CONCLUSION FLAIR was more sensitive than CT in the evaluation of acute SAH in this model, especially when a high volume of SAH was present. This study provides a model for further experimentation with MR imaging in the evaluation of SAH. These findings are consistent with those of current clinical literature, which show FLAIR to be an accurate MR sequence in the diagnosis of SAH.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of magnetic resonance imaging sequences with computed tomography to detect low-grade subarachnoid hemorrhage: Role of fluid-attenuated inversion recovery sequence.

OBJECTIVES To compare computed tomography (CT) with magnetic resonance imaging (MRI) for the presumptive diagnosis and localization of acute and subacute low-grade subarachnoid hemorrhage (SAH). METHODS We consecutively enrolled 45 patients clinically suspected of low-grade SAH, comparing them with a control group. We obtained axial nonenhanced CT scans as well as fluid-attenuated inversion r...

متن کامل

Comparison of fluid-attenuated inversion-recovery MR imaging with CT in a simulated model of acute subarachnoid hemorrhage.

BACKGROUND AND PURPOSE Because MR imaging is becoming integral to the evaluation and treatment of very early stroke, it is critical to prove that MR imaging is at least as sensitive to acute subarachnoid hemorrhage (SAH) as is CT. The present study was conducted to evaluate the possibility of detecting a small amount of acute SAH diluted by CSF not revealed by CT but identified on fluid-attenua...

متن کامل

Diagnosis of Meningitis Caused by Pathogenic Microorganisms Using Magnetic Resonance Imaging: A Systematic Review

Introduction: Bacterial meningitis is an acute infectious inflammation of the protective membranes covering the brain. Its early diagnosis is vital because of its high morbidity and mortality. It is mostly diagnosed by a gold standard diagnostic tool i.e. Cerebrospinal Fluid (CSF) analysis. However, it is sometimes difficult and or impossible to do this procedure and an alternative diagnostic t...

متن کامل

Detecting subarachnoid hemorrhage: comparison of combined FLAIR/SWI versus CT.

OBJECTIVES Aim of this study was to compare the utility of susceptibility weighted imaging (SWI) with the established diagnostic techniques CT and fluid attenuated inversion recovery (FLAIR) in their detecting capacity of subarachnoid hemorrhage (SAH), and further to compare the combined SWI/FLAIR MRI data with CT to evaluate whether MRI is more accurate than CT. METHODS Twenty-five patients ...

متن کامل

Effect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence

Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 22 9  شماره 

صفحات  -

تاریخ انتشار 2001