Tube-side mass transfer for hollow fibre membrane contactors operated in the low Graetz range

نویسندگان

  • C.Y. Wang
  • E. Mercer
  • F. Kamranvand
  • L. Williams
  • A. Kolios
  • A. Parker
  • S. Tyrrel
  • E. Cartmell
  • E.J. McAdam
چکیده

Transformation of the tube-side mass transfer coefficient derived in hollow fibre membrane contactors (HFMC) of different characteristic length scales (equivalent diameter and fibre length) has been studied when operated in the low Graetz range (Gz<10). Within the low Gz range, mass transfer is generally described by the Graetz problem (Sh=3.67) which assumes that the concentration profile comprises a constant shape over the fibre radius. In this study, it is experimentally evidenced that this assumption over predicts mass transfer within the low Graetz range. Furthermore, within the low Gz range (below 2), a proportional relationship between the experimentally determined mass transfer coefficient (Kov ) and the Graetz number has been identified. For Gz numbers below 2, the experimental Sh number approached unity, which suggests that mass transfer is strongly dependent upon diffusion. However, within this diffusion controlled region of mass transfer, tube-side fluid velocity remained important. For Gz numbers above 2, Sh could be satisfactorily described by extension to the Lévêque solution, which can be ascribed to the constrained growth of the concentration boundary layer adjacent to the fibre wall. Importantly this study demonstrates that whilst mass transfer in the low Graetz range does not explicitly conform to either the Graetz problem or classical Lévêque solution, it is possible to transform the experimentally derived overall mass transfer coefficient (Kov ) between characteristic length scales (dh and L). T h is was corroborated by comparison of the empirical relationship determined in this study (Sh=0.36Gz) with previously published studies operated in the low Gz range. This analysis provides important insight for process design when slow tube-side flows, or low Schmidt numbers (coincident with gases) constrain operation of hollow fibre membrane contactors to the low Gz range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling and Simulation of CO2 Absorption Enhancement in Hollow-Fiber Membrane Contactors using CNT–Water-Based Nanofluids

Absorption of CO2 from a gas mixture containing CO2 and nitrogen by water-based CNT nanofluids in gas–liquid hollow fiber membrane contactor was modeled and solved using COMSOL Multiphysics 5.4. The model assumed partial wetting of the membrane, along with diffusion in the axial and radial directions. In addition, Brownian motion and grazing effects were both considered in the model. The main c...

متن کامل

Separation of Carboxylic Acids from Aqueous Solutions using Hollow Fiber Membrane Contactors

Separation of formic, acetic, and propionic acids from the aqueous stream using membrane solvent extraction has been studied using three different membrane contactors made of polysulfone (PS), polyethersulfone (PES), and polyvinylidene fluoride (PVDF) using two different solvents; including ethyl acetate (EA) and diisopropyl ether (DIPE). The efciency of the membrane and e...

متن کامل

Microporous hollow fibre membrane modules as gas- liquid contactors Part 2. Mass transfer with chemical reaction

Absorption determined by mass transfer in the liquid is described well with the Graetz-L&&que equation adapted from heat transfer. The influence of a chemical reaction on the mass transfer was simulated with a numerical model and tested on the absorption of CO2 in a hydroxide solution. Absorption determined by mass transfer in the gas phase and the pores of the membrane was also analysed experi...

متن کامل

بررسی عملکرد تبادل گرهای غشایی الیاف توخالی در علوم پزشکی نوین و داروسازی

Hollow fiber membrane contactors have been applied in various industries e.g. chemistry, petroleum, biotechnology and medicine. They are also widely used in artificial organs e.g. artificial lung, kidney and liver as well as some pharmaceutical procedures such as separation and purification of biological materials. Intrinsic properties of hollow fiber membranes, such as high packing density and...

متن کامل

Theoretical Studies on Copper Extraction by means of Polymeric Membrane Contactors

Solvent extraction of copper in hollow-fiber membrane contactors was investigated in this study. Extraction of copper is carried out conventionally using mixer-settlers. These contactors have some disadvantages such as consumption of high energy, dispersion of two phases and high operating costs. Membrane contactors can obviate the need for conventional contactors. The most favorable module use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 523  شماره 

صفحات  -

تاریخ انتشار 2017