Smith-Petersen Vitallium mould arthroplasty: a 62-year follow-up.

نویسندگان

  • J F Baker
  • M H Vioreanu
  • H A Khan
چکیده

A variety of materials were used for early hip prostheses. The introduction of Vitallium by Smith-Petersen represented a further advance in this surgical field. We present the longest known follow-up of a Smith-Petersen Vitallium mould arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Longest Known Follow-up of a Hip Arthroplasty: The Last Chapter of a 65-Year Long Story

INTRODUCTION The Smith-Petersen vitallium mold arthroplasty was a real landmark in arthroplasty surgery as this was the first technique which produced predictable and satisfactory results. CASE REPORT We present the longest known follow-up of any hip arthroplasty in literature. The arthroplasty was performed in 1949 in London on a 30-years-old female patient with congenital hip dysplasia, and...

متن کامل

The vascular supply to bone in distraction osteoneogenesis: an experimental study.

VOL. 78-B, No. 3, MAY 1996 pain due to gross degenerative changes (Fig. 1). Mr W. Alexander Law at the London Hospital performed a vitallium mould arthroplasty in October 1949 (Fig. 2). She returned to work after eight months and enjoyed an active lifestyle until her retirement in 1984. When seen in January 1995 she walked with a limp but did not require a walking aid and was free from pain. Th...

متن کامل

Smith-Petersen vitallium mould arthroplasty: a 45-year follow-up.

THE JOURNAL OF BONE AND JOINT SURGERY tions, including 24-hour ambulant monitoring, revealed only atrial fibrillation. Radiographs of the cervical spine showed spondylolisthesis at the C5 to C6 level. Anterior cervical interbody fusion was performed at this level; the bony changes seen at operation were similar to those described in case 1. He had no more drop attacks during the last year of hi...

متن کامل

Hip resurfacing arthroplasty

Historical context The concept of resurfacing the hip can be traced back to the early 1900s with the various techniques of interposition arthroplasty.1 Smith-Petersen produced a cast cobalt-molybdenum alloy (vitallium) interposition cup in 1940 as a culmination of many years work with different materials.2 Charnley experimented with a polytetrafluoroethylene (PTFE) hip resurfacing as a clear co...

متن کامل

Mould Arthroplasty of the Knee

Many forms of knee arthroplasty have been described but all are based on one of two principles. The first requires the interposition of material between the bony surfaces after removal of synovial membrane and articular cartilage ; in the second the knee joint is resected and replaced by a metal hinge (Walldius 1957, Shiers 1960). Material interposed between the bony surfaces has included chrom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 93 9  شماره 

صفحات  -

تاریخ انتشار 2011