Partition coefficients of polyphenols for phosphatidylcholine investigated by HPLC with an immobilized artificial membrane column.
نویسندگان
چکیده
The biological activity of polyphenols in vitro reflects their affinity for cell membranes and the amount of cellular incorporation. The interaction of polyphenols with phosphatidylcholine was investigated by HPLC with an immobilized artificial membrane (IAM) column. The IAM partition coefficients (K(IAM)) of the polyphenols, calculated by retention times, correlated well with the amounts of polyphenols incorporation into the liposomes.
منابع مشابه
Screening of Blood-brain Barrier Penetration Using the Immobilized Artificial Membrane Phosphatidylcholine Column Chromatography at the Physiological Ph
In this study, 21 structurally diverse drugs with examined central nervous system penetration were used for prediction of blood-brain barrier penetration using HPLC-UV instrument. Drugs' chromatographic capacity factors were measured by the immobilized artificial membrane presented by phosphatidylcholine column. The correlation between chromatographic capacity factor, octanol-water partition co...
متن کاملQuantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods
Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...
متن کاملQuantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods
Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...
متن کاملImmobilized artificial membrane chromatography: a rapid and accurate HPLC method for predicting bile salt-membrane interactions.
To predict bile salt-membrane interactions physiologically, we used an immobilized artificial membrane HPLC column that contains dimyristoyl-phosphatidylcholine molecules covalently linked to silica microspheres. Using a 90% aqueous (10% acetonitrile) mobile phase, 22 species of bile salts and 4 species of fusidates were eluted. Glycine conjugates displayed higher affinity for the column at pH ...
متن کاملImmobilized lipodisks as model membranes in high-throughput HPLC-MS analysis.
Lipodisks, also referred to as polyethylene glycol (PEG)-stabilized bilayer disks, have previously been demonstrated to hold great potential as model membranes in drug partition studies. In this study, an HPLC-MS system with stably immobilized lipodisks is presented. Functionalized lipodisks were immobilized on two different HPLC support materials either covalently by reductive amination or by ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Bioscience, biotechnology, and biochemistry
دوره 72 12 شماره
صفحات -
تاریخ انتشار 2008