Prevention of arterial graft spasm in rats using a vasodilator-eluting biodegradable nano-scaled fibre.
نویسندگان
چکیده
OBJECTIVES Arterial graft spasm occasionally causes circulatory collapse immediately following coronary artery bypass graft. The aim of this study is to evaluate the efficacy of our developed materials, which were composed of milrinone (phosphodiesterase III inhibitor) or diltiazem (calcium-channel blocker), with nano-scaled fibre made of biodegradable polymer to prevent arterial spasm. METHODS Milrinone- or diltiazem-releasing biodegradable nano-scaled fibres were fabricated by an electrospinning procedure. In vivo milrinone- or diltiazem-releasing tests were performed to confirm the sustained release of the drugs. An in vivo arterial spasm model was established by subcutaneous injection of noradrenalin around the rat femoral artery. Rats were randomly divided into four groups as follows: those that received 5 mg of milrinone-releasing biodegradable nano-scaled fibre (group M, n = 14); 5 mg of diltiazem-releasing biodegradable nano-scaled fibre (group D, n = 12); or those that received fibre without drugs (as a control; group C, n = 14) implanted into the rat femoral artery. In the fourth group, sham operation was performed (group S, n = 10). One day after the implantation, noradrenalin was injected in all groups. The femoral arterial blood flow was measured continuously before and after noradrenalin injection. The maximum blood flow before noradrenalin injection and minimum blood flow after noradrenalin injection were measured. RESULTS In vivo drug-releasing test revealed that milrinone-releasing biodegradable nano-scaled fibre released 78% of milrinone and diltiazem-releasing biodegradable nano-scaled fibre released 50% diltiazem on the first day. The ratios of rat femoral artery blood flow after/before noradrenalin injection in groups M (0.74 ± 0.16) and D (0.72 ± 0.05) were significantly higher than those of groups C (0.54 ± 0.09) and S (0.55 ± 0.16) (P < 0.05). CONCLUSION Noradrenalin-induced rat femoral artery spasm was inhibited by the implantation of milrinone-releasing biodegradable nano-scaled fibre or diltiazem-releasing biodegradable nano-scaled fibre. These results suggested that our materials might be effective for the prevention of arterial graft spasm after coronary artery bypass graft.
منابع مشابه
Pharmacology of coronary artery bypass grafts.
Spasm of arterial and venous graft conduits can occur both during harvesting and after the graft is connected. Attempts to overcome spasm during harvesting by probing or hydraulic distension can cause structural damage to the graft, which may impair short- and long-term patency. After a coronary artery bypass graft is connected, spasm can cause major problems with myocardial perfusion. To selec...
متن کاملPrevention of arterial graft spasm by botulinum toxin: an in-vitro experiment.
In coronary artery bypass surgery, arterial grafts result in improved patency rates. However, these grafts frequently fail due to spasm. Papaverine has been used to prevent graft spasm, but its effect is short-lived. Botulinum toxin inhibits muscle contraction for about three months. We investigated the usefulness of botulinum toxin in preventing arterial grafts spasm in vitro. Samples of abdom...
متن کاملNitroglycerin is preferable to diltiazem for prevention of coronary bypass conduit spasm
Health technology The study focused on the use of two conduit vasodilators in the prevention of arterial conduit spasm after coronary bypass grafting (CABG). Patients received a 24-hour intravenous infusion of either nitroglycerin (0.1 microgram.kg-1.min-1) or diltiazem (0.1 mg/kg during 20 minutes and then 0.1 mg.kg-1.min-1), followed by 6 months of treatment with a daily dose of isosorbide mo...
متن کاملNitroglycerin is preferable to diltiazem for prevention of coronary bypass conduit spasm
Health technology The study focused on the use of two conduit vasodilators in the prevention of arterial conduit spasm after coronary bypass grafting (CABG). Patients received a 24-hour intravenous infusion of either nitroglycerin (0.1 microgram.kg-1.min-1) or diltiazem (0.1 mg/kg during 20 minutes and then 0.1 mg.kg-1.min-1), followed by 6 months of treatment with a daily dose of isosorbide mo...
متن کاملEarly neointimal coverage and vasodilator response following biodegradable polymer sirolimus-eluting vs. durable polymer zotarolimus-eluting stents in patients with acute coronary syndrome –HATTRICK-OCT trial.
BACKGROUND Patients at high bleeding risk would benefit from a shorter dual antiplatelet therapy after PCI. Compared to first-generation devices, the design of newer generation drug-eluting stents may facilitate more rapid anatomical and functional healing of stented vessel based on thinner stent platforms, biodegradable/biocompatible polymers and rapid drug elution. METHODS AND RESULTS Forty...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2013