Constraints to do realistic modeling of the electric field ahead of the tip of a lightning leader

نویسندگان

  • Alexander Broberg Skeltved
  • Nikolai Østgaard
  • Andrew Mezentsev
  • Nikolai Lehtinen
  • Brant Carlson
چکیده

Several computer models exist to explain the observation of terrestrial gamma-ray flashes (TGFs). Some of these models estimate the electric field ahead of lightning leaders and its effects on electron acceleration and multiplication. In this paper, we derive a new set of constraints to do more realistic modeling. We determine initial conditions based on in situ measurements of electric field and vertical separation between the main charge layers of thunderclouds. A maximum electric field strength of 50 kV/cm at sea level is introduced as the upper constraint for the leader electric field. The threshold for electron avalanches to develop of 2.86 kV/cm at sea level is introduced as the lower value. With these constraints, we determine a region where acceleration and multiplication of electrons occur. The maximum potential difference in this region is found to be ∼52 MV, and the corresponding number of avalanche multiplication lengths is ∼3.5. We then quantify the effect of the ambient electric field compared to the leader field at the upper altitude of the negative tip. Finally, we argue that only leaders with the highest potential difference between its tips (∼600 MV) can be candidates for the production of TGFs. However, with the assumptions we have used, these cannot explain the observed maximum energies of at least 40 MeV. Open questions with regard to the temporal development of the streamer zone and its effect on the shape of the electric field remain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Close electric field signatures of dart leader/return stroke sequences in rocket-triggered lightning showing residual fields

[1] Vertical electric field waveforms due to dart leader/return stroke sequences measured on the ground 15 and 30 m from the negative lightning channel are used to examine the so-called residual electric field, the difference between the leader electric field change, and the following return stroke electric field change. At these distances, no residual field is expected if the return stroke neu...

متن کامل

Registration of X-rays at 2500m altitude in association with lightning flashes and thunderstorms

Electric fields and high-energy radiation of natural lightning measured at close range from a mountaintop tower are discussed. In none of the 12 negative cloud-to-ground upward flashes were X-rays observed. Also no energetic radiation was found in one negative upward leader at close range (20m). In the first of two consecutive negative cloud-to-ground flashes, X-rays were detected during the la...

متن کامل

Electrospinning of Polyacrylonitrile Nanofibers and Simulation of Electric Field via Finite Element method

Objective(s): Since the electric field is the main driving force in electrospinning systems, the modeling and analysis of electric field distribution are critical to the nanofibers production. The aim of this study was modeling of the electric field and investigating the various parameters on polyacrylonitrile (PAN) nanofibers morphology and diameter. Methods:</st...

متن کامل

Journal of Geophysical Research: Atmospheres Streamer formation and branching frommodel hydrometeors in subbreakdown conditions inside thunderclouds

Electric field values measured inside thunderclouds have consistently been reported to be up to an order of magnitude lower than the value required for the conventional electrical breakdown of air. This result has made it difficult to explain how lightning frequently occurs in thunderclouds. A few different theories have been offered to explain the lightning initiation process, one of them bein...

متن کامل

Initiation and Development of Lightning Discharge: Physical Mechanism and Basic Problems

This paper considers three interconnected problems: (i) initiation of a downward lightning in a thundercloud and that of an upward lightning near tall grounded structures; (ii) conditions for lightning development in the cloud-to-ground gap and the effects of lightning trajectory and branching on discharge parameters; and (iii) physical mechanism of the lightning return stroke and peculiarities...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 122  شماره 

صفحات  -

تاریخ انتشار 2017