Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty.

نویسندگان

  • Young-Hoo Kim
  • Jun-Shik Kim
  • Yoowang Choi
  • Oh-Ryong Kwon
چکیده

BACKGROUND Whether total knee arthroplasty with use of computer-assisted surgical navigation can improve the limb and component alignment is a matter of debate. We hypothesized that total knee arthroplasty with use of computer-assisted surgical navigation is superior to conventional total knee arthroplasty with regard to the precision of implant positioning. METHODS Sequential simultaneous bilateral total knee arthroplasties were carried out in 160 patients (320 knees). One knee was replaced with use of a computer-assisted surgical navigation system, and the other was replaced conventionally without use of computer-assisted surgical navigation. The two methods were compared for accuracy of orientation and alignment of the components as determined by radiographs and computed tomography scans. The mean duration of follow-up was 3.4 years. RESULTS The mean preoperative Knee Society score was 26 points, with an improvement to 92 points postoperatively, in the computer-assisted total knee arthroplasty group and 25 points, with an improvement to 93 points postoperatively, in the conventional total knee arthroplasty group. Preoperative and postoperative ranges of motion of the knees were similar in both groups. The operating and tourniquet times were significantly longer in the computer-assisted total knee arthroplasty group than in the conventional total knee arthroplasty group (p < 0.001). The groups were not significantly different with regard to the accuracy of component positioning and the number of outliers for the various radiographic parameters (p > 0.05). CONCLUSIONS Our data demonstrate that total knee arthroplasty with use of computer-assisted surgical navigation did not result in more accurate implant positioning than that achieved in conventional total knee arthroplasty, as determined by both radiographs and computed tomography scans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computer Assisted Navigation in Knee Arthroplasty

Computer assisted surgery (CAS) was used to improve the positioning of implants during total knee arthroplasty (TKA). Most studies have reported that computer assisted navigation reduced the outliers of alignment and component malpositioning. However, additional sophisticated studies are necessary to determine if the improvement of alignment will improve long-term clinical results and increase ...

متن کامل

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study.

Bilateral sequential total knee replacement was carried out under one anaesthetic in 100 patients. One knee was replaced using a CT-free computer-assisted navigation system and the other conventionally without navigation. The two methods were compared for accuracy of orientation and alignment of the components. There were 85 women and 15 men with a mean age of 67.6 years (54 to 83). Radiologica...

متن کامل

Computer Assisted Total Knee Arthroplasty: Does it Make a Difference?

ABSTRACT The longevity of total knee prostheses depends mostly on the correct alignment (frontal, sagittal and axial) of the prosthetic components, soft tissue balancing and restoring the mechanical axis of the lower limb.The use of computer-assisted navigation allows more accurate and reproducible restoration of mechanical axis and component positioning, better results in patients with extra-a...

متن کامل

Radiographic results of an accelerometer-based, handheld surgical navigation system for the tibial resection in total knee arthroplasty.

In total knee arthroplasty (TKA), intramedullary and extramedullary tibial alignment guides are not proven to be highly accurate in obtaining alignment perpendicular to the mechanical axis in the coronal plane. The objective of this study was to determine the accuracy of an accelerometer-based, handheld surgical navigation system in obtaining a postoperative tibial component alignment within 2°...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 91 1  شماره 

صفحات  -

تاریخ انتشار 2009