Refined flicker photometry technique to measure ocular lens density.
نویسندگان
چکیده
Many physiological and pathological conditions are associated with a change in the crystalline lens transmittance. Estimates of lens opacification, however, generally rely on subjective rather than objective measures in clinical practice. The goal of our study was to develop an improved psychophysical heterochromatic flicker photometry technique combined with existing mathematical models to evaluate the spectral transmittance of the human ocular media noninvasively. Our results show that it is possible to accurately estimate ocular media density in vivo in humans. Potential applications of our approach include basic research and clinical settings on visual and nonimage-forming visual systems.
منابع مشابه
Comparison between macular pigment optical density measurements using two-wavelength autofluorescence and heterochromatic flicker photometry techniques.
PURPOSE The association of macular pigment (MP) with age-related macular degeneration has been extensively studied in recent years, and interest in a rapid, objective, and accurate technique to measure MP optical density (MPOD) has increased. The purpose of this study was to compare the MPOD values at specific loci around the fovea using the heterochromatic flicker photometry (HFP) and the two-...
متن کاملMacular pigment density measured by autofluorescence spectrometry: comparison with reflectometry and heterochromatic flicker photometry.
We present a technique for estimating the density of the human macular pigment noninvasively that takes advantage of the autofluorescence of lipofuscin, which is normally present in the human retinal pigment epithelium. By measuring the intensity of fluorescence at 710 nm, where macular pigment has essentially zero absorption, and stimulating the fluorescence with two wavelengths, one well abso...
متن کاملOnline Appendix Macular Pigment Optical Density (MPOD) Testing in the Elderly: Development of a Simplified and Abbreviated Testing Protocol to Minimize Fatigue and Participant Burden
The most commonly and most extensively validated method used to measure MPOD is a psychophysical test based on heterochromatic flicker photometry (HFP). 2 This method determines psychophysically the ratio between the visual sensitivity for a flickering test light that is maximally absorbed by MPs alternating in counterphase with a suppressing background at a wavelength that is not absorbed by t...
متن کاملOptical density of the human lens.
Optic disk reflectance was measured from 27 normal observers with their physiological lenses (aged 21-74 yr) and from two pseudophakic observers (aged 69 and 70 yr) with use of a Utrecht fundus reflection densitometer. Psychophysical heterochromatic flicker photometric luminance matches (10 degrees field) were obtained on the same group of the observers. A four-parameter model incorporating len...
متن کاملA portable instrument for measuring macular pigment with central fixation.
PURPOSE To evaluate the reliability and validity of a portable instrument for measuring macular pigment optical density. METHODS The instrument is small, uses light emitting diodes as light sources and the principles of heterochromatic flicker photometry of comparing foveal and extra-foveal minimum flicker matches. It uses central fixation for the extra-foveal matches, which subjects found ea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 29 11 شماره
صفحات -
تاریخ انتشار 2012