Ventilator-associated pneumonia with circuit changes every 2 days versus every week.
نویسندگان
چکیده
BACKGROUND Frequent ventilator circuit changes are expensive and sometimes unnecessary. Following the worldwide trend to lengthen the intervals for ventilator circuit change from 2 days to 1 week, this study aims to assure that low rate of ventilator-associated pneumonia (VAP) can be maintained with cost containment. METHODS Ventilator circuits were routinely changed every 7 days in the study period for 2 years and every 2 days during the historical control period of another 2 years. Pediatric patients (age less than 15 years) were not included. Nosocomial pneumonia was diagnosed by the criteria of the Centers of Disease Control and Prevention (CDC) of the United States (US). VAP was identified by combining and comparing 2 databases from the Respiratory Therapy Department and the Infection Control Unit of our hospital. RESULTS In the study group, 225 episodes of pneumonias were observed in 7,068 patients and 87,338 ventilator days. The rate of VAP was 2.58 per 1,000 ventilator days. There were 174 episodes of pneumonia in 6,213 patients and 65,467 ventilator days of the control group. The rate of VAP was 2.66 per 1,000 ventilator days. The difference between both groups was not significant (p = 0.803). Yet, the cost curbed was around 80,000 US dollars per year. CONCLUSIONS Extending ventilator circuit change interval from 2 days to 7 days do not increase the risk for VAP, but the cost savings for labor and supply are substantial.
منابع مشابه
Effect of ventilator circuit changes on ventilator-associated pneumonia: a systematic review and meta-analysis.
BACKGROUND Recent guidelines concerning prevention of ventilator-associated pneumonia recommend that ventilator circuits should not be changed routinely, but in practice circuit changes at regular intervals persist. METHODS We searched the MEDLINE, EMBASE, and SCOPUS databases and reviewed citations to identify articles that reported the results of randomized controlled trials and sequential ...
متن کاملEvaluation of the Effects of Oronasal Versus Oral Disinfections with Chlorhexidine on Clinical Criteria of Ventilator-associated Pneumonia
Background: Ventilator-associated pneumonia (VAP) is the most prevalent and lethal form of nosocomial infections in the ICU and oral disinfection is a nursing measure to prevent this condition. Aim: this study aimed to evaluate the effect of oronasal versus oral disinfections with chlorhexidine on the clinical criteria for diagnosis of VAP. Method: This randomized clinical trial was conducted o...
متن کاملExtending ventilator circuit change interval beyond 2 days reduces the likelihood of ventilator-associated pneumonia.
OBJECTIVE To determine the risk of acquiring ventilator-associated pneumonia (VAP) and the impact on costs when extending ventilator circuit change intervals beyond 2 days to 7 and 30 days. DESIGN Prospective 4-year review of mechanically ventilated patients. SETTING The respiratory and medical ICUs of an 800-bed tertiary teaching Veterans Affairs hospital. PATIENTS All adult patients rec...
متن کاملWeekly ventilator circuit changes. A strategy to reduce costs without affecting pneumonia rates.
BACKGROUND Mechanical ventilator circuits are commonly changed at 48-h intervals. This frequency may be unnecessary because ventilator-associated pneumonia often results from aspiration of pharyngeal secretions and not from the ventilator circuit. We compared the ventilator-associated pneumonia rates and costs associated with 48-h and 7-day circuit changes. METHODS Ventilator circuits were ch...
متن کاملWeekly versus daily changes of in-line suction catheters: impact on rates of ventilator-associated pneumonia and associated costs.
BACKGROUND An earlier randomized, controlled trial showed that weekly or as-needed (as opposed to daily) changes of in-line suction catheters were associated with substantial cost savings, without a higher rate of ventilator-associated pneumonia (VAP). To examine the impact of decreasing the frequency of in-line suction catheter changes in our medical intensive care unit, we conducted an observ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Zhonghua yi xue za zhi = Chinese medical journal; Free China ed
دوره 64 3 شماره
صفحات -
تاریخ انتشار 2001