Field mapping without reference scan using asymmetric echo-planar techniques.
نویسندگان
چکیده
Improvements in Bo mapping and shimming were achieved by measuring the static field information in multiple subsequent echoes generated by an asymmetric echo-planar readout gradient train. With careful compensation, eddy current effects were shown to affect the adjustment of the shim coils minimally. In addition to reducing the time required for field mapping by two-fold, the sensitivity was simultaneously optimized irrespective of the prevalent T2* present, thereby minimizing the error of the static field measurement to below 0.1 Hz. With adiabatic low flip-angle excitation, the time required for field mapping was below 1 second.
منابع مشابه
A novel object-independent "balanced" reference scan for echo-planar imaging.
Interleaved echo-planar imaging (EPI) is susceptible to significant ghosting artifacts, resulting primarily from system time delays that cause data matrix misregistration. Most EPI applications rely on "reference scans" to measure delays, and post-processing algorithms are used to correct these errors. Unfortunately, delay estimates made with most reference scan techniques are object dependent,...
متن کاملRapid T(1) mapping using multislice echo planar imaging.
Determination of neurological pathology in white matter disease can be made in a semiquantitative way from T(1)- or T(2)-weighted images. A higher level of quantification based on measured T(1) or T(2) values has been either limited to specific regions of interest or to low-resolution maps. Higher-resolution T(1) maps have proved difficult to obtain due to the excessively long scan times requir...
متن کاملA referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐13C]pyruvate and [1‐13C]lactate
Single-shot echo planar imaging (EPI), which allows an image to be acquired using a single excitation pulse, is used widely for imaging the metabolism of hyperpolarized 13 C-labelled metabolites in vivo as the technique is rapid and minimizes the depletion of the hyperpolarized signal. However, EPI suffers from Nyquist ghosting, which normally is corrected for by acquiring a reference scan. In ...
متن کاملAn Efficient Correction Technique for Constant, Linear and ‘Oblique’ Phase Errors in EPI-PROPELLER
Introduction Short-axis and long-axis PROPELLER echo planar imaging (referred to as SAP-EPI and LAP-EPI, respectively) [1, 2] have been developed as alternatives to fast spin echo (FSE)-based PROPELLER sequences [3]. EPI-PROPELLER typically requires fewer shots than FSE-PROPELLER, and is less SAR-intensive. Like other EPI sequences, however, both SAPand LAP-EPI are sensitive to eddy currents th...
متن کاملGeometric distortion correction in echo volumar imaging
Introduction: Echo volumar imaging (EVI) is a 3D extension of echo-planar imaging (EPI) that allows data from an entire volume to be acquired following a single excitation. However, only a few studies to date have applied EVI to functional MRI (fMRI) due to its high sensitivity to field-inhomogeneity induced distortions. In this study, we extend two EPI distortion correction techniques to EVI: ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 43 2 شماره
صفحات -
تاریخ انتشار 2000