Contrast sensitivity in patients with posterior chamber intraocular lens implants.
نویسندگان
چکیده
Divergent contrast sensitivity findings have been reported in patients with intraocular lens implants. In this study, contrast sensitivity to stationary sine-wave gratings of six spatial frequencies from 0.5 to 22.8 cycles/degree was measured psychophysically in 13 patients with posterior chamber intraocular lens implants and in 10 controls. Corrected visual acuity was 0.7 to 1.0 in the intraocular lens group and 0.9 to 1.0 in the reference group. The age, the pupil diameter and the rate of subtle age-related macular changes were equal in the two groups. No statistically significant difference in mean contrast sensitivity between the patients and the controls was observed at any spatial frequency examined.
منابع مشابه
Iris-sutured posterior chamber intraocular lens implantation during penetrating keratoplasty.
PURPOSE To evaluate the clinical indications and postoperative results of iris-sutured posterior chamber intraocular lens implants performed during penetrating keratoplasty. METHODS Medical records were retrospectively reviewed for preoperative indications and postoperative results of 342 consecutive patients (366 eyes) who underwent iris suturing of a posterior chamber intraocular lens impla...
متن کاملComparison of Patient's Satisfaction Level after Different Types of Posterior Chamber Intraocular Lens Implantation
Objective. To compare patient's satisfaction level in performing routine activities during daylight and night vision after implantation with rigid, foldable, or rollable posterior chamber intraocular lens implants in uneventful cataract surgery. Design. Retrospective, cross-sectional. Place and Duration of Study. PNS SHIFA Hospital, Karachi, from Nov. 2009 to Nov. 2010. Methodology. 91 cataract...
متن کاملAspheric versus Spherical Posterior Chamber Intraocular Lenses
PURPOSE To compare spherical aberration and contrast sensitivity function following implantation of four different foldable posterior chamber intraocular lenses (IOLs), namely Sensar, Akreos AO, Tecnis, and AcrySof IQ. METHODS In this randomized clinical trial, 68 eyes of 68 patients with senile cataracts underwent phacoemulsification and IOL implantation with Sensar (n=17), Akreos AO (n=17),...
متن کاملPhakic posterior chamber lenses for high myopia: functional and anatomical outcomes.
PURPOSE To evaluate the functional and the anatomical outcomes after implantation of phakic posterior chamber intraocular lenses (IOLs) in highly myopic eyes. SETTING Service d'Ophtalmologie, Hôpital Purpan, Toulouse, France. METHODS Fifty-eight eyes of 46 patients that had implantation of phakic posterior chamber lenses for high myopia were evaluated. Predictability, efficiency, safety, an...
متن کاملSecondary intraocular lens implantation in University Hospital, Kuala Lumpur.
Secondary intraocular lens implantation after cataract surgery done in University Hospital between 1983 to 1993 were reviewed. Thirty three patients (37 eyes) underwent secondary intraocular lens implantation during this period. Twenty four eyes had secondary anterior chamber lens implantation while 13 had posterior chamber lens implantation. There was no case of secondary posterior scleral fix...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta ophthalmologica
دوره 66 4 شماره
صفحات -
تاریخ انتشار 1986